Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Pseudorabies virus (PRV), porcine parvovirus (PPV) and porcine circovirus 3 (PCV3) are common in swine farms in China. Single infection or co-infection with PRV, PPV and/or PCV3 was difficult to distinguish between their clinical symptoms and pathological changes. Therefore, a quick and accurate detection method is needed for epidemiological surveillance, disease management, import and export control.
Methods: In the present study, we established a multiplex real-time PCR assay based on SYBR Green I for the simultaneous detection of PRV, PPV and PCV3 genomes.
Results: PRV, PPV and PCV3 were distinguished in the same sample by their different melting temperatures (Tm), with melting peaks at 90 °C for PRV, 84 °C for PPV and 80 °C for PCV3, respectively, and other non-targeted swine pathogens did not exhibit specific melting peaks. The assay showed a high degree of linearity (R≧0.995), and the detection limits were 4.76 copies/μL for PRV, 3.67 copies/μL for PPV, 3.07 copies/μL for PCV3 and 1.87 × 10 copies/μL for the three mixed plasmids, respectively. In this research, 81 clinical samples from pig farms in nine different regions of Guangdong Province were used to evaluate this new method. The detection rate of the multiplex real-time PCR assay was higher than that of the conventional PCR assay.
Conclusions: This multiplex real-time PCR assay could be used as a diagnostic tool that is rapid, sensitive and reliable for the detection of co-infection of PRV, PPV and PCV3 as well as for molecular epidemiological surveillance.