A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars. | LitMetric

Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars.

Sensors (Basel)

College of Automation & College of Artificial Intelligence, Nanjing University of Posts and Telecommunications, Nanjing 210023, China.

Published: December 2024

The design and study of pulsed eddy current sensors for detecting surface defects in small-diameter rods are highly significant. Accurate detection and identification of surface defects in small-diameter rods may be attained by the ongoing optimization of sensor design and enhancement of detection technologies. This article presents the construction of a non-coaxial differential eddy current sensor (Tx-Rx sensor) and examines the detection of surface defects in a small diameter bar. A COMSOL 3D model is developed to examine the variations in eddy current distribution and defect signal characteristics between the plate and rod components. The position of the excitation coil on the bar and the eddy current disruption around the defect are examined. Additionally, a Tx-Rx sensor has been developed and enhanced concerning coil dimensions, coil separation, and elevation height. An experimental system is established to detect bar structures with surface defects of varying depths, and a model correlating differential signal attenuation with defect depth is proposed, achieving a quantitative relative error of less than 5%, thereby offering a reference for the quantitative detection of bar surface defects.

Download full-text PDF

Source
http://dx.doi.org/10.3390/s24248063DOI Listing

Publication Analysis

Top Keywords

surface defects
24
eddy current
20
defects small-diameter
12
design study
8
study pulsed
8
pulsed eddy
8
current sensor
8
detecting surface
8
small-diameter rods
8
tx-rx sensor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!