A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of Inductive Current Transformer 400/5/1 of Class 0.2S for Frequency Range 50 Hz-5 kHz. | LitMetric

Development of Inductive Current Transformer 400/5/1 of Class 0.2S for Frequency Range 50 Hz-5 kHz.

Sensors (Basel)

Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland.

Published: December 2024

This paper is devoted to the development of a window-type inductive current transformer (iCT) with a rated primary current equal to 400 A and two secondary windings with rated currents of 5 A and 1 A. Its novelty concerns the presentation of this process in the case of an iCT with a 0.2S accuracy class ensured not only for a sinusoidal current of a frequency of 50 Hz but also for the transformation of distorted current in the harmonic frequency range from 50 Hz to 5 kHz. The maximum permissible values of the current error and phase displacement are equal to ±0.2% and ±0.2°, respectively, and are the same as the limiting values for a 50 Hz sinusoidal current of a rated RMS value. In the design process, three materials were considered for the construction of the developed iCT 400/5/1: electrical steel, permalloy and nanocrystalline (Nano). Their wideband properties were analyzed and the choice of the Nano magnetic core was justified with the already-available data in the literature on the basis of elaborated design assumptions. In order to specify its particular type, four magnetic cores with different initial magnetic permeabilities were tested. It was demonstrated that, as far as more favorable magnetic properties also involved increased active power losses in the magnetic core, it was not an appropriate choice for the construction of the iCT, especially for the transformation of the current with a main frequency equal to 50 Hz or 60 Hz.

Download full-text PDF

Source
http://dx.doi.org/10.3390/s24248011DOI Listing

Publication Analysis

Top Keywords

current
8
inductive current
8
current transformer
8
frequency range
8
sinusoidal current
8
magnetic core
8
magnetic
5
development inductive
4
transformer 400/5/1
4
400/5/1 class
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!