A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Rapidly Tunable Laser System for Measurements of NH at 597 nm Behind Reflected Shock Waves. | LitMetric

Distributed feedback lasers, which feature rapid wavelength tunability, are not presently available in the yellow and orange spectral regions, impeding spectroscopic studies of short-lived species that absorb light in this range. To meet this need, a rapidly tunable laser system was constructed, characterized, and demonstrated for measurements of the NH radical at 597.4 nm. The system consisted of three main parts: (1) a distributed feedback diode laser operating at 1194.8 nm, (2) a fiber-coupled optical amplifier, and (3) a periodically poled lithium niobate (PPLN) waveguide for second-harmonic generation. A phase-matching optical frequency bandwidth of 118 GHz and a second-harmonic generation efficiency of 109%/W were determined for the PPLN waveguide, and the intensity and wavelength stability of the system were measured. The rapid-tuning capabilities of the laser system were characterized to explore its potential for use in scanned-direct absorption and wavelength modulation spectroscopy experiments. The feasibility of scanned-direct absorption up to a scan rate of 900 kHz and wavelength modulation spectroscopy at modulation frequencies up to 800 kHz were demonstrated. Finally, the system was deployed in a series of shock tube experiments in which the concentration of NH radicals was measured during the decomposition of NH behind reflected shock waves.

Download full-text PDF

Source
http://dx.doi.org/10.3390/s24247920DOI Listing

Publication Analysis

Top Keywords

laser system
12
rapidly tunable
8
tunable laser
8
reflected shock
8
shock waves
8
distributed feedback
8
ppln waveguide
8
second-harmonic generation
8
scanned-direct absorption
8
wavelength modulation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!