A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Range Expansion Technology for Ring MEMS Gyroscopes Based on Drive Voltage Modulation. | LitMetric

Range Expansion Technology for Ring MEMS Gyroscopes Based on Drive Voltage Modulation.

Micromachines (Basel)

School of Instrument and Electronics, North University of China, Taiyuan 030051, China.

Published: November 2024

This paper proposes a method to control the sensitivity of a ring MEMS gyroscope by adjusting the driving control voltage via MEMS. The aim is to explore the relationship between the range of the ring MEMS gyroscope and the driving control voltage, establishing a mathematical model that correlates driving control voltage with sensitivity. By applying different driving voltages to the same gyroscope, the study evaluates the performance and range of the gyroscope. Experimental results demonstrate that lower driving voltages increase the gyroscope's range. At a driving voltage of 10.85 V, the gyroscope achieves a range of ±200°/s, a minimum resolution of 0.019°/s, and a nonlinearity of 22.37 ppm. At 1.46 V, the gyroscope range expands to ±1000°/s, with a minimum resolution of 0.05138°/s and a nonlinearity of 60.73 ppm. As the measurement range increased fivefold, the degradation in gyroscope performance was significantly less than the scale of range expansion. Compared to the gain in modulation detection circuitry, gyroscope performance was optimized across the entire operational range.

Download full-text PDF

Source
http://dx.doi.org/10.3390/mi15121419DOI Listing

Publication Analysis

Top Keywords

ring mems
12
driving control
12
control voltage
12
range
9
range expansion
8
gyroscope
8
mems gyroscope
8
driving voltages
8
minimum resolution
8
gyroscope performance
8