A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis Profiling of 48 Endogenous Amino Acids and Related Compounds in Human Plasma Using Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry. | LitMetric

Analysis Profiling of 48 Endogenous Amino Acids and Related Compounds in Human Plasma Using Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry.

Molecules

Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven, 3000 Leuven, Belgium.

Published: December 2024

Analyzing and detecting endogenous amino acids in blood is of crucial importance for the diagnosis of medical conditions and scientific research. Considering the lack of UV chromophores in most of these analytes and the presence of several interfering substances in plasma, the quantification of quite a few amino acids and related compounds presents certain technical challenges. As a blank plasma matrix lacking these endogenous substances does not exist, the surrogate matrix method is used, as well as isotopic internal standards for calibration, to ensure the accuracy and reliability of the study. Method validation was conducted for 48 target analytes, giving the following results: linearity (R at least 0.99), limit of quantification (from 0.65 to 173.44 μM), precision (intra-day and inter-day RSD for LQC ranged from 3.2% to 14.2%, for MQC from 2.0% to 13.6%, and for HQC from 1.6% to 11.3%), accuracy, recovery, and stability of the method (all complied with the guidelines). To further investigate the applicability of this method to large-scale sample analysis, the method was successfully applied to the analysis of amino acids in plasma samples collected from 20 control individuals, demonstrating its wide application scope for clinical diagnosis and metabolic research.

Download full-text PDF

Source
http://dx.doi.org/10.3390/molecules29245993DOI Listing

Publication Analysis

Top Keywords

amino acids
16
endogenous amino
8
acids compounds
8
method
5
analysis profiling
4
profiling endogenous
4
amino
4
acids
4
compounds human
4
plasma
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!