The use of motorized nickel titanium instruments is an essential component in contemporaneous clinical endodontics. The mechanical properties of nickel titanium are optimal for the cleaning and shaping of root canal systems. However, instrumentation carries risks, particularly instrument fracture, which may become an obstacle to achieving adequate disinfection of the canal system. Although the biomechanics of instrument fracture have been extensively investigated previously, certain facets remain unexplored, specifically torsional fatigue. This review presents a comprehensive overview of the modern understanding of the biomechanics involved in nickel titanium instrument fracture. Importantly, while research has tended to describe fatigue fracture and torsional failure as distinct and separate entities, clinical conditions are likely a combination of the two. Moreover, intracanal instrument fractures may also occur following a different mechanism, torsional fatigue. This should be taken into consideration for further research and clinical guidance.

Download full-text PDF

Source
http://dx.doi.org/10.3390/ma17246147DOI Listing

Publication Analysis

Top Keywords

nickel titanium
16
instrument fracture
16
titanium instrument
8
root canal
8
torsional fatigue
8
instrument
5
fracture
5
biomechanics nickel
4
titanium
4
fracture root
4

Similar Publications

Objective: The present study aimed to evaluate the phase transformation behavior and elemental analysis of thermomechanical-treated nickel-titanium (NiTi) rotary instruments, TruNatomy (Dentsply Sirona), HyFlex CM (coltene, Whaledent), and Neoendo Flex (Orikam healthcare India), using differential scanning calorimetry (DSC), X-ray diffraction (XRD), and energy dispersive X-ray spectrometry.

Materials And Methods: A total of 18 NiTi rotary instruments, TruNatomy, Hyflex CM, Neoendo Flex, taper. 04, size 25 (except TruNatomy, size 26) were selected and were divided into three groups ( = 6).

View Article and Find Full Text PDF

The use of motorized nickel titanium instruments is an essential component in contemporaneous clinical endodontics. The mechanical properties of nickel titanium are optimal for the cleaning and shaping of root canal systems. However, instrumentation carries risks, particularly instrument fracture, which may become an obstacle to achieving adequate disinfection of the canal system.

View Article and Find Full Text PDF

The finite element method (FEM) is an advanced numerical technique that can be applied in orthodontics to study tooth movements, stresses, and deformations that occur during orthodontic treatment. It is also useful for simulating and visualizing the biomechanical behavior of teeth, tissues, and orthodontic appliances in various clinical scenarios. The objective of this research was to analyze the mechanical behavior of teeth, tissues, and orthodontic appliances in various clinical scenarios.

View Article and Find Full Text PDF

Background Fracture of nickel-titanium (Ni-Ti) instruments in root canals is commonly associated with compromised outcomes in endodontic treatment. There is no single, universally accepted approach for managing this complication. The objective of this study is to evaluate the effectiveness of an Nd: YAP laser-assisted protocol in removing fractured Ni-Ti files in teeth with minimal root curvature (less than 15 degrees).

View Article and Find Full Text PDF

Objective: This study aimed at determining the effect of pH changes on nickel titanium wire seen based on the corrosion rate and surface roughness of the wire after immersion in pandan leaves extract.

Material And Methods: The sample used nickel titanium wire of 0.016 inches diameter and 5 cm length and consists of five treatment groups: control group, 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!