AI Article Synopsis

Article Abstract

Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted. The CW-CVD process allows the coating of 3D structures, minimizing thermal stress on the surrounding equipment and allowing the deposition of coatings on temperature-sensitive materials. It produces uniform and high-purity films with control over the thickness and composition. The reduced heating of the chamber walls minimizes unwanted reactions, leading to fewer impurities in the final coating. The graphene layers obtained using Raman spectroscopy at different parameters of the CW-CVD process were verified, their properties were investigated, and the functional mechanical behavior of the studied graphene-covered stent was confirmed. In vitro, graphene-coated stents promoted rapid endothelial cell repopulation, an advantage over gold-standard drug-eluting stents delaying re-endothelialization. Also, full-range biocompatibility studies on potential allergic, irritation, toxicological, and pyrogenic reactions of new material in vivo on small animal models demonstrated excellent biocompatibility of the graphene-coated stents.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11728169PMC
http://dx.doi.org/10.3390/ijms252413345DOI Listing

Publication Analysis

Top Keywords

mechanical behavior
12
functional mechanical
8
cw-cvd process
8
graphene-coated stents
8
behavior biocompatible
4
biocompatible characteristics
4
characteristics graphene-coated
4
graphene-coated cardiovascular
4
stents
4
cardiovascular stents
4

Similar Publications

Ductilization of 2.6-GPa alloys via short-range ordered interfaces and supranano precipitates.

Science

January 2025

Center for Advancing Materials Performance from the Nanoscale (CAMP-Nano), Hysitron Applied Research Center in China (HARCC) and Center for Alloy Innovation and Design (CAID), State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, China.

Higher strength and higher ductility are desirable for structural materials. However, ultrastrong alloys inevitably show decreased strain-hardening capacity, limiting their uniform elongation. We present a supranano (<10 nanometers) and short-range ordering design for grain interiors and grain boundary regions, respectively, in fine-grained alloys based on vanadium, cobalt, and nickel, with additions of tungsten, copper, aluminum, and boron.

View Article and Find Full Text PDF

Enzymes are attractive as catalysts due to their specificity and biocompatibility; however, their use in industrial and biomedical applications is limited by stability. Here, we present a facile approach for enzyme immobilization within "all-enzyme" hydrogels by forming photochemical covalent cross-links between the enzyme glucose oxidase. We demonstrate that the mechanical properties of the enzyme hydrogel can be tuned with enzyme concentration and the data suggests that the dimeric nature of glucose oxidase results in unusual gel formation behavior which suggests a degree of forced induced dimer dissociation and unfolding.

View Article and Find Full Text PDF

Sensing light's polarization and wavefront direction enables surface curvature assessment, material identification, shadow differentiation, and improved image quality in turbid environments. Traditional polarization cameras utilize multiple sensor measurements per pixel and polarization-filtering optics, which result in reduced image resolution. We propose a nanophotonic pipeline that enables compressive sensing and reduces the sampling requirements with a low-refractive-index, self-assembled optical encoder.

View Article and Find Full Text PDF

Exposure to Secondhand Cannabis Smoke Among Children.

JAMA Netw Open

January 2025

Herbert Wertheim School of Public Health and Human Longevity Science, University of California, San Diego.

Importance: The degree that in-home cannabis smoking can be detected in the urine of resident children is unclear.

Objective: Test association of in-home cannabis smoking with urinary cannabinoids in children living at home.

Design, Setting, And Participants: This cross-sectional study used baseline data from Project Fresh Air, a 2012-2016 randomized clinical trial to reduce fine particulate matter levels.

View Article and Find Full Text PDF

Long-term durability and temporal pattern of revisional surgery of laparoscopic large hiatal hernia repair.

Updates Surg

January 2025

Department of Surgical Sciences, General Surgery and Center for Minimally Invasive Surgery, University of Torino, Corso A.M. Dogliotti 14, 10126, Turin, Italy.

Laparoscopic repair is the preferred surgical treatment for symptomatic Large Hiatal Hernia (LHH). However, data on long-term outcomes are limited. This study aims to evaluate the 20-year follow-up results of laparoscopic LHH repair in a high-volume experienced tertiary center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!