Recently, laparoscopic nephrectomy has become more popular in veterinary medicine. In the majority of these procedures, vascular sealing devices (VSDs) are used. These allow for the closure of renal vessels with advanced bipolar coagulation. However, until now, closure of the ureter was performed with mechanical clips or suturing. There is a lack of information in the literature about the possibility of VSDs being used for ureter closure. This article presents the possibility of renal vessels and ureter closure in cats and dogs with vascular sealing devices. Laparoscopic nephrectomy in dogs and cats was performed entirely with VSDs. Patients with unilateral hydronephrosis qualified for the procedure. The nephrectomies were completely performed using a laparoscopic approach. Both renal vasculature and ureter were closed with VSDs. Additionally, two resected ureters from operated cats underwent histopathological evaluation. Among the operated animals, there were no postoperative complications or signs in the urinary tract. Histopathological evaluation of two cats' ureters showed lumen closure on the coagulation places. Vascular sealing devices, during laparoscopic nephrectomy, allow for closure of not only the renal vessels but also ureters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/life14121681 | DOI Listing |
J Artif Organs
January 2025
Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shinmachi, Suita, Osaka, 5648565, Japan.
This review traces the evolution of centrifugal blood pumps in mechanical circulatory support (MCS) systems. Initially met with concerns over blood damage and thrombus formation, centrifugal pumps have become crucial components in ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO) due to their simplified drive mechanisms and adaptability. This paper outlines three generations of centrifugal pump development: first-generation pumps with sealing components, second-generation pumps utilizing pivot bearings, and third-generation pumps employing contactless bearings.
View Article and Find Full Text PDFLife (Basel)
December 2024
Department and Clinic of Surgery, Faculty of Veterinary Medicine, Wroclaw University of Environmental and Life Sciences, 50-366 Wroclaw, Poland.
Recently, laparoscopic nephrectomy has become more popular in veterinary medicine. In the majority of these procedures, vascular sealing devices (VSDs) are used. These allow for the closure of renal vessels with advanced bipolar coagulation.
View Article and Find Full Text PDFJSLS
January 2025
Department of Medical and Surgical Gynecology, Mayo Clinic College of Medicine & Science, Jacksonville, FL. (Drs. Horton, Coombs, and Cardenas-Trowers).
Background: Hysterectomy is one of the most common surgical procedures performed in the United States and most are now being performed in a minimally invasive approach. Electrosurgery and vessel sealing devices are needed in order to provide hemostasis and vascular coaptation; however, there is no guiding evidence and limited recommendations for the use of the currently available devices for laparoscopic hysterectomy. The purpose of this study is to provide a systematic review of electrosurgical devices used in benign hysterectomy and perform a meta-analysis to find the overall effect of various outcomes.
View Article and Find Full Text PDFRev Cardiovasc Med
December 2024
Department of Cardiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011 Shanghai, China.
Catheter Cardiovasc Interv
December 2024
Department of Cardiology, Angiology and Intensive Care Medicine, University Heart Center Lübeck, Lübeck, Germany.
Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.
Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!