Recently, laparoscopic nephrectomy has become more popular in veterinary medicine. In the majority of these procedures, vascular sealing devices (VSDs) are used. These allow for the closure of renal vessels with advanced bipolar coagulation. However, until now, closure of the ureter was performed with mechanical clips or suturing. There is a lack of information in the literature about the possibility of VSDs being used for ureter closure. This article presents the possibility of renal vessels and ureter closure in cats and dogs with vascular sealing devices. Laparoscopic nephrectomy in dogs and cats was performed entirely with VSDs. Patients with unilateral hydronephrosis qualified for the procedure. The nephrectomies were completely performed using a laparoscopic approach. Both renal vasculature and ureter were closed with VSDs. Additionally, two resected ureters from operated cats underwent histopathological evaluation. Among the operated animals, there were no postoperative complications or signs in the urinary tract. Histopathological evaluation of two cats' ureters showed lumen closure on the coagulation places. Vascular sealing devices, during laparoscopic nephrectomy, allow for closure of not only the renal vessels but also ureters.

Download full-text PDF

Source
http://dx.doi.org/10.3390/life14121681DOI Listing

Publication Analysis

Top Keywords

sealing devices
16
laparoscopic nephrectomy
16
devices laparoscopic
12
vascular sealing
12
renal vessels
12
advanced bipolar
8
nephrectomy dogs
8
dogs cats
8
allow closure
8
closure renal
8

Similar Publications

Progress of extracorporeal centrifugal pumps for mechanical circulatory supports.

J Artif Organs

January 2025

Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shinmachi, Suita, Osaka, 5648565, Japan.

This review traces the evolution of centrifugal blood pumps in mechanical circulatory support (MCS) systems. Initially met with concerns over blood damage and thrombus formation, centrifugal pumps have become crucial components in ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO) due to their simplified drive mechanisms and adaptability. This paper outlines three generations of centrifugal pump development: first-generation pumps with sealing components, second-generation pumps utilizing pivot bearings, and third-generation pumps employing contactless bearings.

View Article and Find Full Text PDF

Recently, laparoscopic nephrectomy has become more popular in veterinary medicine. In the majority of these procedures, vascular sealing devices (VSDs) are used. These allow for the closure of renal vessels with advanced bipolar coagulation.

View Article and Find Full Text PDF

Electrosurgical Devices Used During Laparoscopic Hysterectomy.

JSLS

January 2025

Department of Medical and Surgical Gynecology, Mayo Clinic College of Medicine & Science, Jacksonville, FL. (Drs. Horton, Coombs, and Cardenas-Trowers).

Background: Hysterectomy is one of the most common surgical procedures performed in the United States and most are now being performed in a minimally invasive approach. Electrosurgery and vessel sealing devices are needed in order to provide hemostasis and vascular coaptation; however, there is no guiding evidence and limited recommendations for the use of the currently available devices for laparoscopic hysterectomy. The purpose of this study is to provide a systematic review of electrosurgical devices used in benign hysterectomy and perform a meta-analysis to find the overall effect of various outcomes.

View Article and Find Full Text PDF
Article Synopsis
  • Left atrial appendage closure (LAAC) is an alternative for patients with nonvalvular atrial fibrillation (NVAF) to avoid oral anticoagulants, but issues like incomplete device endothelialization (IDE) can lead to complications.
  • A study compared the endothelialization rates after implantation of two devices: the Watchman plug and the LACBES occluder, in 201 patients, using cardiac computed tomography angiography (CCTA).
  • Results showed that the LACBES occluder had a higher IDE rate at both 3 and 6 months compared to the Watchman device, indicating that it takes longer for the LACBES to achieve complete endothelialization after LAAC.
View Article and Find Full Text PDF

Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.

Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!