Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Assessing objective physical function in patients with cancer is crucial for evaluating their ability to tolerate invasive treatments. Current assessment methods, such as the timed up and go (TUG) test and the short physical performance battery, tend to require additional resources and time, limiting their practicality in routine clinical practice. To address these challenges, we developed a system to assess physical function based on movements observed during clinical consultations and aimed to explore relevant features from inertial measurement unit data collected during those movements. As for the flow of the research, we first collected inertial measurement unit data from 61 patients with cancer while they replicated a series of movements in a consultation room. We then conducted correlation analyses to identify keypoints of focus and developed machine learning models to predict the TUG test outcomes using the extracted features. Regarding results, pelvic velocity variability (PVV) was identified using Lasso regression. A linear regression model using PVV as the input variable achieved a mean absolute error of 1.322 s and a correlation of 0.713 with the measured TUG results during five-fold cross-validation. Higher PVV correlated with shorter TUG test results. These findings provide a foundation for the development of an artificial intelligence-based physical function assessment system that operates without the need for additional resources.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/bioengineering11121232 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!