Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: This study compared the visual outcomes and optical quality of two monofocal, aspheric intraocular lenses (IOLs; CT LUCIA 621P, Carl Zeiss Meditec; Eyhance ICB00, Johnson & Johnson Vision) by evaluating visual acuity, contrast sensitivity, and higher-order aberrations 1 month post-cataract surgery.
Methods: In this retrospective, comparative study, 120 eyes (72 patients) that underwent cataract surgery with either CT LUCIA 621P (Lucia group) or Eyhance ICB00 (Eyhance group) implantation (60 eyes/group) were retrospectively investigated. Visual acuity at various distances and defocus curves were measured 1 month postoperatively. Optical quality was assessed by comparing contrast sensitivity and internal coma, spherical, and total aberrations by using iTrace (Tracey Technology), a ray-tracing-type aberrometer.
Results: The visual acuity and defocus curves were similar between the two IOLs 1 month postoperatively. The Lucia group showed better contrast sensitivity at higher spatial frequencies: 12 cpd ( < 0.001, 1.32 LogCS vs. 1.02 LogCS) and 18 cpd ( = 0.009, 0.74 LogCS vs. 0.47 LogCS) unilaterally and 18 cpd ( = 0.044, 0.94 LogCS vs. 0.60 LogCS) bilaterally. Postoperative internal spherical aberration was significantly lower in the Lucia group ( < 0.001, -0.04 µm vs. -0.003 µm). Internal coma and total aberrations were similar.
Conclusions: The visual acuity and defocus curves of the Lucia and Eyhance groups were comparable 1 month post-cataract surgery. The Lucia group's superior contrast sensitivity and lower postoperative internal spherical aberration were due to differences in IOL designs, particularly the power variation patterns.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/diagnostics14242862 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!