Background: The rapid growth of aesthetic medicine has led to an increased demand for non-surgical cosmetic procedures in the frontal region of the face. However, alongside this rise in popularity, there is a growing awareness of the potential complications associated with these procedures especially connected with fillers. The intricate vascular anatomy of the forehead, specifically the supratrochlear (STA) and supraorbital (SOA) arteries, poses significant risks if not thoroughly understood. While the morphological course of these vessels is well-documented and analysed, detailed knowledge about their depth remains vital for enhancing procedural safety.

Materials And Methods: Five research papers were analyzed in the meta-analysis. The analyses of STA and SOA were performed in two distinctive places bilaterally: at the level of the glabella and above the eyebrow.

Results: A total of 201 SOA arteries and 282 STA arteries were analysed at the following horizontal levels, respectively: at the level of the glabella and above the eyebrow. The final results were as follows: 5.68 mm, 95% CI (4.58-6.78) for SOA at the glabella, 5.53 mm, 95% CI (4.79-6.28) for SOA above the eyebrow, 4.45 mm, 95% CI (3.43-5.47) for STA at the glabella, and 3.53 mm, 95% CI (3.21-3.85) for STA above the eyebrow.

Conclusions: The supratrochlear artery tends to become more superficial along its path, while the supraorbital artery remains at a consistent depth across various anatomical levels. For injections in the medial part of the forehead, it is advisable to place the needle up to 2.5 mm deep or laterally to the artery's path. In contrast, injections in the lateral part of the forehead can be administered at slightly deeper depths, up to 3.5 mm. To minimise the risk of complications, performing a high-resolution linear ultrasonography (USG) exam prior to injection is recommended, allowing for needle placement either laterally or medially to the vessels.

Download full-text PDF

Source
http://dx.doi.org/10.5603/fm.103774DOI Listing

Publication Analysis

Top Keywords

soa arteries
8
level glabella
8
sta
5
soa
5
depth arterial
4
arterial supply
4
forehead
4
supply forehead
4
forehead meta-analysis
4
meta-analysis background
4

Similar Publications

Background: The rapid growth of aesthetic medicine has led to an increased demand for non-surgical cosmetic procedures in the frontal region of the face. However, alongside this rise in popularity, there is a growing awareness of the potential complications associated with these procedures especially connected with fillers. The intricate vascular anatomy of the forehead, specifically the supratrochlear (STA) and supraorbital (SOA) arteries, poses significant risks if not thoroughly understood.

View Article and Find Full Text PDF

Background: The European Chronic Thromboembolic Pulmonary Hypertension (CTEPH) registry, conducted between 2007 and 2012, reported the major impact of pulmonary endarterectomy (PEA) on the long-term survival of patients with CTEPH. Since then, 2 additional treatments for inoperable CTEPH have become available: balloon pulmonary angioplasty (BPA), and an approved oral drug therapy with the guanylate cyclase stimulator riociguat. The current registry aimed to evaluate the effect of these new therapeutic approaches in a worldwide context.

View Article and Find Full Text PDF
Article Synopsis
  • The article examines the safety of aesthetic procedures in the forehead, particularly the glabella area, which is known for its complex vascular structure.
  • A database search resulted in the review of 25 studies focusing on the arterial anatomy of the forehead, utilizing methods like cadaveric dissection and Doppler ultrasonography.
  • The findings highlight significant variability in the locations of key arteries, suggesting that medical professionals need to be cautious of high-risk zones when performing dermatologic procedures in this area.
View Article and Find Full Text PDF

We report a first and interesting case of balloon-assisted deployment of a dislodged coronary stent. While performing a calcified left circumflex coronary artery (LCX) intervention, the drug-eluting coronary stent was dislodged in the osteoproximal segment of the calcified and tortuous LCX. The dislodged stent was rewired, progressively dilated with multiple balloons and, finally, a larger, balloon-mounted stent was pushed forward, positioned across the coronary lesion and deployed, resulting in distal thrombolysis in myocardial infarction (TIMI) III flow with good angiographic results.

View Article and Find Full Text PDF

Background: Pulmonary artery to left atrium fistula is an unusual structural cause of silent cyanosis. Only less than 100 cases have been reported so far. A high index of clinical suspicion and proper evaluation with bubble contrast echocardiography and cardiac computed tomography (CT) will help to detect this treatable anomaly.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!