Objective: Despite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.

Method: FNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM). This study created a solid model with images of femur bone tomography. Dynamic hip screws (DHS), cannulated screws (CCS), and medial buttress plates (MBP) were obtained by making three-dimensional designs. The required elements for the models were assigned, and the material properties of the elements were defined. The solutions were obtained as crack distance and deformation results after defining the boundary conditions and applying the necessary loading.

Results: The strain and crack distance values created by six models on the fracture line under different parameters were obtained, and the numerical results were evaluated. The DHS and CCS models produced the highest crack distance and deformation values when all screws were loose. The lowest values were obtained in the intact-85 model when all CCS were tight. When the results are evaluated, it is seen that the MBP has a decreasing effect on the results. Mechanical evaluation of six different options used in femoral neck fractures was performed. 85 mm CCS applied to our standard model gave the best results, while the use of 80 mm CCS in the same model showed promising results compared to other models. It is understood that CCS have the best stability even in loosening models with the medial support plate. Different models are from intact-85 mm DHS+1CS+MBP to DHS+1CS, which was worked with LSR+USR-2, according to decreasing stability.

Conclusion: This study offers various biomechanical solutions to possible intraoperative problems in FNF treatment. The following results were obtained from the study data. When the CCS needs to be lengthened or replaced, it is appropriate to use the CCS with the MBP. A single anti-rotation screw is sufficient for lag screw extensions of the DHS plate, and the MBP may be a savior procedure in surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1111/os.14337DOI Listing

Publication Analysis

Top Keywords

femoral neck
12
crack distance
12
solution suggestions
8
neck fracture
8
finite element
8
element method
8
fnf treatment
8
ccs
8
distance deformation
8
models
6

Similar Publications

Rationale And Objectives: Accurate assessment of hip morphology is crucial for the diagnosis and management of hip pathologies. Traditional manual measurements are prone to mistakes and inter- and intra-reader variability. Artificial intelligence (AI) could mitigate such issues by providing accurate and reproducible measurements.

View Article and Find Full Text PDF

We report the case of a 72-year-old woman who was admitted following a fall and sustained a right neck of femur fracture. Prior to this admission, she was undergoing chemotherapy for lung cancer. Upon this admission, it was noted that she had developed neutropenic sepsis.

View Article and Find Full Text PDF

Purpose: Hip fractures in elderly individuals are associated with high mortality rates, even with advanced treatment options. Identifying factors correlated with mortality could guide potential preventive strategies. Elevated aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels, as well as the AST/ALT ratio (AAR), have been associated with mortality in various diseases, but their association with hip fracture mortality remains underexplored.

View Article and Find Full Text PDF

Evaluation of bone mineral density and its influencing factors in patients infected with HIV under antiretroviral therapy.

BMC Infect Dis

January 2025

Department of Infectious Diseases, School of Medicine, Iranian Research Center for HIV/AIDS, Iranian Institute for Reduction of High Risk Behaviors, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.

Background: Reduced Bone Mineral Density (BMD) has been linked to Human Immunodeficiency Virus (HIV) infection and treatment. There is a lack of information regarding the osteoporosis status of middle-aged patients with HIV in Iran, despite the fact that Antiretroviral Therapy (ART) is widely accessible.

Objective: The purpose of this cross-sectional study was to assess the BMD status and low BMD risk factors in patients with HIV under ART living in Iran.

View Article and Find Full Text PDF

Objective: Despite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.

Method: FNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!