A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mass Spectrometric Detection of Keratins in Tear Fluid. | LitMetric

Mass Spectrometric Detection of Keratins in Tear Fluid.

Exp Eye Res

Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, Augusta, GA 30912; Department of Ophthalmology, Medical College of Georgia, Augusta University, Augusta, GA 30912. Electronic address:

Published: January 2025

Purpose: Keratin contamination is a common problem in mass spectrometry proteomic analyses, particularly in bottom-up mass spectrometry. The purpose of this study was to determine the protein contaminants introduced during the proteomic analysis of tear fluid.

Methods: Human tear fluid samples were collected using Schirmer strips. Proteomic analyses were performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) on blank Schirmer strips and tear fluid samples, with empty vials serving as controls for assessing environmental contaminant proteins.

Results: We detected 26 contaminant proteins (18 keratins and 8 non-keratins). 98.2% of the total protein contamination can be attributed to the 9 keratins, including KRT10 (23.6%), KRT1 (23.5%), KRT2 (15.7%), KRT14 (7.6%), KRT16 (7.0%), KRT5 (6.1%), KRT9 (5.9%), KRT6B (4.6%), and KRT6A (4.3%). A comparison to the proteomic profile of blank Schirmer strips and controls (empty vials) found a strong correlation (R=0.9753), indicating that these proteins were not from the blank Schirmer strips but are environmental contaminants. On the other hand, several keratins including KRT19, KRT13, KRT4, KRT7, KRT15, KRT8 and KRT18 were present in tear fluid, but either not detected or were negligible in blank strips. Another set of keratins, including KRT5, KRT6A, KRT14, KRT16, and KRT17, were identified as components of tear fluid as well as environmental contaminants.

Conclusions: This study revealed nine major contaminant keratins in the mass spectrometry analysis. Several other keratins were identified as constituents of tear fluid. Background subtraction is necessary for the accurate analysis of tear fluid using mass spectrometry.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.exer.2025.110231DOI Listing

Publication Analysis

Top Keywords

tear fluid
28
mass spectrometry
20
schirmer strips
16
blank schirmer
12
keratins including
12
tear
8
proteomic analyses
8
analysis tear
8
fluid samples
8
empty vials
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!