Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Keratin contamination is a common problem in mass spectrometry proteomic analyses, particularly in bottom-up mass spectrometry. The purpose of this study was to determine the protein contaminants introduced during the proteomic analysis of tear fluid.
Methods: Human tear fluid samples were collected using Schirmer strips. Proteomic analyses were performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) on blank Schirmer strips and tear fluid samples, with empty vials serving as controls for assessing environmental contaminant proteins.
Results: We detected 26 contaminant proteins (18 keratins and 8 non-keratins). 98.2% of the total protein contamination can be attributed to the 9 keratins, including KRT10 (23.6%), KRT1 (23.5%), KRT2 (15.7%), KRT14 (7.6%), KRT16 (7.0%), KRT5 (6.1%), KRT9 (5.9%), KRT6B (4.6%), and KRT6A (4.3%). A comparison to the proteomic profile of blank Schirmer strips and controls (empty vials) found a strong correlation (R=0.9753), indicating that these proteins were not from the blank Schirmer strips but are environmental contaminants. On the other hand, several keratins including KRT19, KRT13, KRT4, KRT7, KRT15, KRT8 and KRT18 were present in tear fluid, but either not detected or were negligible in blank strips. Another set of keratins, including KRT5, KRT6A, KRT14, KRT16, and KRT17, were identified as components of tear fluid as well as environmental contaminants.
Conclusions: This study revealed nine major contaminant keratins in the mass spectrometry analysis. Several other keratins were identified as constituents of tear fluid. Background subtraction is necessary for the accurate analysis of tear fluid using mass spectrometry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.exer.2025.110231 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!