Impact of leadless pacemaker implantation site on cardiac synchronization and tricuspid regurgitation.

Egypt Heart J

Department of Cardiology, Hangzhou First People's Hospital, #261 Huansha Road, Hangzhou, 310000, Zhejiang Province, China.

Published: January 2025

AI Article Synopsis

Article Abstract

Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.

Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging. Intraoperative and 1-month post-operative echocardiography was performed to assess cardiac electromechanical synchronization and tricuspid regurgitation; parameters of interest included interventricular mechanical delay (IVMD), pre-ejection period of the aorta (L-PEI), and septal-to-posterior wall motion delay (SPWMD). Pacing thresholds, sensing, and impedance exhibited no significant differences between the 8/9 zone and other sites (P > 0.05). In contrast, the 8/9 zone group manifested a significant reduction in L-PEI (128.24 ± 12.27 vs. 146.50 ± 18.17 ms, P < 0.001), IVMD (17.92 ± 8.47 vs. 28.56 ± 15.16 ms, P < 0.001), and SPWMD (72.84 ± 19.57 vs. 156.56 ± 81.54 ms, P < 0.001), compared to the non-8/9 group. Post-pacing QRS duration showed no significant difference between the two groups (139.21 ± 11.36 vs. 143.83 ± 16.35 ms P = 0.310). Notably, for patients with atrial fibrillation, the 8/9 zone placement significantly reduced tricuspid regurgitation. During the 1-month follow-up, neither group reported major complications such as bleeding, cardiac tamponade, pacemaker detachment, or malignant arrhythmias.

Conclusion: Implantation of the leadless pacemaker in the right ventricular 8/9 zone provides superior electromechanical synchronization compared to other sites.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11704105PMC
http://dx.doi.org/10.1186/s43044-024-00602-2DOI Listing

Publication Analysis

Top Keywords

leadless pacemaker
12
synchronization tricuspid
12
pacemaker implantation
8
implantation site
8
tricuspid regurgitation
8
8/9 zone
8
impact leadless
4
site cardiac
4
cardiac synchronization
4
regurgitation background
4

Similar Publications

Background: Immune checkpoint inhibitors (ICIs) are effective antineoplastic agents but can cause adverse effects in many organ systems. Cardiovascular toxicities include arrhythmias, myocarditis, heart failure, takotsubo syndrome, pericarditis, coronary artery disease, and vasculitis.

Case Summary: A 66-year-old woman with Stage 3C2 endometrial carcinoma presented for her second cycle of pembrolizumab, carboplatin, and paclitaxel.

View Article and Find Full Text PDF

Unlabelled: Corrected transposition of the great arteries (c-TGA) is a congenital abnormality characterized by atrioventricular (AV) and ventriculoarterial discordance, associated with early and late-onset conduction disturbances. We report the case of a c-TGA patient affected by congenital complete AV block, with right ventricular lead malfunction with prolonged dwell time and two abandoned leads. He underwent leadless VDD pacemaker implantation at an unusual site (i.

View Article and Find Full Text PDF

Background: Removal of cardiac implantable electronic devices (CIEDs) is strongly recommended for CIED-related infections, and leadless pacemakers (LPs) are increasingly used for reimplantation. However, the optimal timing and safety of LP implantation after CIED removal for infection remains unclear.This systematic review and meta-analysis aimed to assess complication rates (all-cause mortality and reinfection) when LP implantation was performed simultaneously with or after CIED removal.

View Article and Find Full Text PDF

A video demonstration presents the retrieval of a dislodged leadless pacemaker using the double-snare technique. Sharing troubleshooting strategies in such cases is clinically important for managing rare pacemaker complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!