A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Memory enhancement by transcranial radiofrequency wave treatment occurs without appreciably increasing brain temperature. | LitMetric

We have previously shown in small studies that full brain Transcranial Radiofrequency Wave Treatment (TRFT) to subjects with Alzheimer's Disease could stop and reverse their cognitive decline. An 8-emitter head device, the "MemorEM", was used in these studies to provide TRFT at 915 MHz frequency and power level of 1.6 W/kg Specific Absorption Rate (SAR) during daily 1-hour treatments. Although no deleterious side effects during up to 2.5 years of treatment were reported, it is important to rule out the possibility that brain heating will occur during TRFT in humans at a higher power level of 4.0 W/kg SAR, which is anticipated for future clinical testing in order to increase treatment intensity/efficacy to deep sub-cortical areas. To examine if brain heating occurs during a single 1-hour treatment at 4 W/kg SAR, a hollow human head phantom filled with brain-analogous gel and with an attached MemorEM head device was utilized. Brain temperatures were taken at 64 specific coordinates within the brain gel before and immediately following one-hour of TRFT. Results revealed none of the 64 sites having a temperature increase after TRFT of 1 °C or more. Indeed, 45 of the 64 sites exhibited a temperature rise of less than 0.5 °C, with just three sites exhibiting an increase between 0.75 and 0.9 °C. These results demonstrate that TRFT in a human head phantom that mimics the electromagnetic properties of the human head, does not appreciably increase brain temperature (i.e., is non-thermal) at 915 MHz frequency and 4 W/kg SAR power level. Thus, TRFT would appear to be safe at 4 W/kg for long-term daily treatments.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-024-01508-8DOI Listing

Publication Analysis

Top Keywords

power level
12
human head
12
transcranial radiofrequency
8
radiofrequency wave
8
wave treatment
8
brain temperature
8
head device
8
915 mhz frequency
8
brain heating
8
4 w/kg sar
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!