A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ossicular Chain Reconstruction With Glass Ionomer Cement Following Removal of Active Middle Ear Implant. | LitMetric

Ossicular Chain Reconstruction With Glass Ionomer Cement Following Removal of Active Middle Ear Implant.

OTO Open

Shohet Ear Associates Medical Group Inc. Orange County California USA.

Published: January 2025

The use of bone cement in ossicular chain reconstruction (OCR) represents an area of recent interest. This multi-institutional retrospective study assesses the efficacy of glass ionomer cement (GIC) in OCR following the explantation of a fully implantable active middle ear implant. A postoperative 4-frequency mean air-bone gap (ABG) was obtained for 15 subjects by averaging 0.5, 1, 2, and 4 kHz frequencies. For Group A (short-term, N = 15), at a mean of 4.5 months postoperatively, 9 (60%) achieved an ABG between 0 and 10 dB, 5 (33%) were 11 to 20 dB, and 1 (7%) was 21 to 30 dB. For Group B (long-term, N = 5), at a mean of 50 months postoperatively, 4 (80%) were 0 to 10 dB and 1 (20%) was 11 to 20 dB. These results suggest that GIC represents an effective means of ABG closure after device explantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11696887PMC
http://dx.doi.org/10.1002/oto2.70062DOI Listing

Publication Analysis

Top Keywords

ossicular chain
8
chain reconstruction
8
glass ionomer
8
ionomer cement
8
active middle
8
middle ear
8
ear implant
8
months postoperatively
8
reconstruction glass
4
cement removal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!