Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing.

ACS Omega

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration & National Clinical Research Center for Oral Diseases & Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, Shaanxi, P. R. China.

Published: December 2024

Metal 3D printing has been used in the manufacturing of dental implants. Its technical advantages include high material utilization and the capacity to form arbitrarily complex structures. However, 3D printing alone is insufficient for manufacturing two-stage titanium implants due to the limited precision in printing titanium alloy parts. In this study, 3D printing was employed to create the implant structure, subsequently complemented by mechanical processing to refine the implant abutment connection and neck. Additionally, the mechanical properties of 3D-printed titanium alloy implants were evaluated through tensile and dynamic fatigue testing. The MTT assay was employed to assess the cytotoxicity of 3D-printed titanium alloy dental implants. The impact of bone union and osteogenesis from 3D-printed titanium alloy dental implants was investigated through in vivo experimentation. The results demonstrated that combining 3D printing with subsequent machining constitutes a viable method for the manufacture of two-stage titanium dental implants. Test results for mechanical properties indicated that heat-treated 3D-printed titanium alloy dental implants possess significant tensile strength and fatigue resistance and are capable of withstanding the robust chewing forces in the oral cavity. In vitro findings revealed that sandblasted and acid-etched 3D-printed titanium alloy exhibited negligible cytotoxicity, with osteoblast differentiation of hMSCs being more pronounced compared with the control group. In vivo studies indicated that no significant differences were observed in bone volume fraction, bone-implant contact rate, and unscrewing torque between 3D-printed titanium alloy dental implants and commercial SLA surface implants at both 1 and 3 months postimplantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11696423PMC
http://dx.doi.org/10.1021/acsomega.4c09131DOI Listing

Publication Analysis

Top Keywords

titanium alloy
32
dental implants
24
3d-printed titanium
24
alloy dental
20
two-stage titanium
12
titanium
10
implants
9
alloy
8
mechanical properties
8
dental
7

Similar Publications

Objectives: This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments.

Materials And Methods: A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer's recommended torque.

View Article and Find Full Text PDF

Antibacterial and Anti-Inflammation Activity of Titanium Alloy by Efficient Copper Immobilization.

Langmuir

January 2025

Department of Biomaterials, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.

Titanium alloy plates are often used for fixation to bone. However, the plates often need to be removed due to infection and adverse inflammation. To avoid these problems, we immobilized copper, which has antibacterial effects and low cytotoxicity, on titanium plates by immersing the titanium in copper-tris(hydroxymethyl)aminomethane complex solutions.

View Article and Find Full Text PDF

Hydroxyapatite (HAP) nano-coatings on titanium alloys (for example, Ti6Al4V) have been used for prosthetic orthopedic implants in recent decades due to their osseointegration, bioactivity, and biocompatibility. HAP is brittle with low mechanical strength and poor adhesion on metallic surfaces, which limits its durability and bioactivity. Surface modification techniques have alleviated the imperfection of biomaterials by coating the substrate.

View Article and Find Full Text PDF

The potential of hydrogen plasma arc technology for the efficient deoxygenation and recycling of titanium alloy scrap is explored. The results of thermodynamic analysis reveal that hydrogen plasma is suitable for oxygen removal. The intermediate stages of the deoxygenation process are sequentially analyzed, showing that the hydrogen plasma arc primarily facilitated the reduction and dissolution of oxides as well as eliminated interstitial oxygen.

View Article and Find Full Text PDF

Researchers have modified PLA materials to enhance their mechanical properties and meet the clinical requirements. However, the strength and stiffness of PLA are still significantly lower than those of metals. Building on the established chevron clinical procedure and considering the mechanical characteristics of PLA screws, we devised a modified chevron osteotomy (MCO) based on a load-reducing structure with the aim of reducing the load on the screws.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!