A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of pH on the release of nickel ions from fixed orthodontic appliances in artificial saliva. | LitMetric

Aim: The aim of this study was to make a laboratory assessment of pH influence on the kinetics of the release of nickel ions in artificial saliva.

Methods And Material: In this study, 15 basic orthodontic appliances are immersed in 15 polyethylene tubes each containing 40 ml of artificial saliva. Tubes were divided into three sub-groups of 5 tubes depending on the pH: pH 5, pH 7 and pH 8. The release of nickel ions was measured using atomic absorption spectrometry in a sample of 5 ml of artificial saliva taken one hour, four hours and one hundred and sixty-eight hours after immersion in a water bath at 37°.

Statistical Analysis Used: Significance threshold was set at 0.05. A Student T test and the 2-way Anova test (with a Bonferoni post-test) were used respectively to compare the means.

Results: The neutral pH causes a low release of nickel ions. The release kinetics of nickel ions is minimal for neutral pH, it increases when pH varies. After one hour of immersion, the nickel released did not reach the spectrometer quantification threshold as for neutral and acid pH. The alkaline pH causes an average release of nickel ions from the beginning without kinetic variation. As time passes (T3), the acidic pH causes more nickel ions release through a succession of oxidation-reduction reactions. After 168 hours, the average mass of nickel released is 0.30 µg for pH 7, 1.35 µg for pH 8 and up to 2.85 µg for pH 5.

Conclusions: Quantities released did not reach nickel toxicity threshold in humans. Orthodontists must consider the potential risk of hypersensitivity due to nickel in fixed orthodontic appliances.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11698249PMC
http://dx.doi.org/10.4103/jos.jos_8_24DOI Listing

Publication Analysis

Top Keywords

nickel ions
28
release nickel
20
orthodontic appliances
12
artificial saliva
12
nickel
11
fixed orthodontic
8
ions release
8
nickel released
8
released reach
8
ions
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!