A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Chiral Porous Organic Polymer Used as the Stationary Phase for High-Resolution Gas Chromatography Separations. | LitMetric

A chiral porous organic polymer (cPOP) was synthesized through nucleophilic substitution polymerization between dichloromaleimide and aromatic amine. This cPOP was used as a new chiral stationary phase (CSP) for gas chromatography (GC) chiral separation. In this work, we first used this cPOP as the CSP for gas chromatography to investigate its ability to separate racemic mixtures, including amino acid derivatives, chiral alcohols, aldehydes, alkanes, ketones, esters, and organic acids. The results showed that the column can effectively separate various racemic mixtures and achieve baseline separation of threonine (Rs = 1.91). Furthermore, the separation mechanism was elucidated by density functional theory (DFT) simulation. Additionally, the cPOP column demonstrated good repeatability and stability. The relative standard deviations (RSDs) for intraday were 0.11%-0.12% (n = 3) for the retention time of n-butyl glycidyl ether, 0.1%-0.34% (n = 3) for interday, and 2.25%-3.37% (n = 3) for column to column. This work shows that cPOP has good potential as chiral stationary phases in gas chromatography.

Download full-text PDF

Source
http://dx.doi.org/10.1002/chir.70011DOI Listing

Publication Analysis

Top Keywords

gas chromatography
16
chiral porous
8
porous organic
8
organic polymer
8
stationary phase
8
chiral stationary
8
csp gas
8
work cpop
8
separate racemic
8
racemic mixtures
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!