A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Enhanced Efficiency of Sequential Cutting Balloon Angioplasty in Calcified Coronary Artery Disease: The RODIN-CUT Technique. | LitMetric

Background: Heavily calcified coronary artery disease presents significant challenges in percutaneous coronary intervention (PCI), often requiring advanced techniques to achieve optimal outcomes. Cutting balloons (CB) have shown potential for plaque modification; however, their effectiveness is limited without standardized protocols.

Aims: This study introduces the RODIN-CUT technique, a novel approach utilizing sequential CB inflations with real-time intravascular ultrasound (IVUS) guidance. The technique aims to enhance calcified plaque modification, improve stent expansion, and achieve consistent procedural success in heavily calcified coronary lesions.

Methodology: A retrospective analysis of three consecutive patients requiring specialized approaches beyond conventional PCI was included at three centers in Belgium. The RODIN-CUT protocol involved multiple CB inflations at precise lesion segments, followed by immediate IVUS imaging after each inflation to assess plaque modification and guide further therapy. Procedural success was defined as residual stenosis < 30% with TIMI 3 distal flow. The study evaluated the dose-dependent effects of repeated CB inflations on plaque fracture depth and distribution.

Conclusion: The RODIN-CUT technique demonstrated promising outcomes, achieving procedural success in all cases with enhanced stent expansion and minimal complications. The technique's simplicity, cost-effectiveness, and reproducibility make it a viable option for treating heavily calcified coronary lesions. Further large-scale studies are required to validate these findings and establish the RODIN-CUT technique as a standard approach for complex calcified lesions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.31387DOI Listing

Publication Analysis

Top Keywords

calcified coronary
12
plaque modification
12
coronary artery
8
artery disease
8
rodin-cut technique
8
heavily calcified
8
procedural success
8
enhanced efficiency
4
efficiency sequential
4
sequential cutting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!