Purpose: During endovascular revascularization interventions for peripheral arterial disease, the standard modality of X-ray fluoroscopy (XRF) used for image guidance is limited in visualizing distal segments of infrapopliteal vessels. To enhance visualization of arteries, an image registration technique was developed to align pre-acquired computed tomography (CT) angiography images and to create fusion images highlighting arteries of interest.

Methods: X-ray image metadata capturing the position of the X-ray gantry initializes a multiscale iterative optimization process, which uses a local-variance masked normalized cross-correlation loss to rigidly align a digitally reconstructed radiograph (DRR) of the CT dataset with the target X-ray, using the edges of the fibula and tibia as the basis for alignment. A precomputed library of DRRs is used to improve run-time, and the six-degree-of-freedom optimization problem of rigid registration is divided into three smaller sub-problems to improve convergence. The method was tested on a dataset of paired cone-beam CT (CBCT) and XRF images of ex vivo limbs, and registration accuracy at the midline of the artery was evaluated.

Results: On a dataset of CBCTs from 4 different limbs and a total of 17 XRF images, successful registration was achieved in 13 cases, with the remainder suffering from input image quality issues. The method produced average misalignments of less than 1 mm in horizontal projection distance along the artery midline, with an average run-time of 16 s.

Conclusion: The sub-mm spatial accuracy of artery overlays is sufficient for the clinical use case of identifying guidewire deviations from the path of the artery, for early detection of guidewire-induced perforations. The semiautomatic workflow and average run-time of the algorithm make it feasible for integration into clinical workflows.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-024-03302-zDOI Listing

Publication Analysis

Top Keywords

x-ray image
8
image registration
8
xrf images
8
average run-time
8
x-ray
5
registration
5
registration improved
4
improved visualization
4
visualization tibial
4
tibial vessels
4

Similar Publications

Background And Aim: Qualitative diagnosis of ulcerative colitis-associated neoplasia (UCAN) is crucial for surveillance colonoscopy in patients with ulcerative colitis (UC). Although the utility of magnifying endoscopy with narrow-band imaging (ME-NBI) in sporadic neoplasia diagnosis has been reported, its efficacy in UCAN remains unclear. This study aimed to evaluate the usefulness of ME-NBI for qualitative diagnosis of UCAN.

View Article and Find Full Text PDF

Background: McKittrick-Wheelock syndrome is an uncommon and severe disorder caused by large hypersecretory tumors located in the distal colorectal area. Excessive secretion from adenomas is an unusual clinical manifestation that leads to severe electrolyte and fluid depletion, subsequently resulting in kidney injury. Successful treatment relies on quick and cooperative decision-making for timely intervention.

View Article and Find Full Text PDF

Background: In COPD patients with severe right-sided emphysema, complete major and incomplete minor fissure, implantation of one-way valves in both the right upper (RUL) and middle lobes (ML) is a possible approach for endoscopic lung volume reduction. The aim of this retrospective analysis was to evaluate the response to therapy and the complication rate at 90 days (90d-FU) after combined RUL-ML valve implantation.

Methods: This retrospective, monocentric study included all patients from the Thoraxklinik Heidelberg who underwent RUL-ML valve treatment between 2012 and 2023 with available follow-up data.

View Article and Find Full Text PDF

Cessation of thumb/finger sucking habit in children using electronic habit reminder versus palatal crib: a randomized clinical pilot study.

BMC Oral Health

January 2025

Paediatric Dentistry and Dental Public Health Department, Faculty of Dentistry, Cairo University, EL-Saraya Street, Cairo, Egypt.

Background: There are different intraoral appliances for cessation of thumb/finger sucking habit, but they have many disadvantages and to overcome it, extra oral appliances with colourful and attractive shape were developed. Electronic habit reminder in the form of wristwatch with alarming sound was assessed in cessation of thumb/finger sucking habit in children versus palatal crib after 6 and 9 months.

Methods: This study is a randomized clinical pilot study, with allocation ratio 1:1 parallel group.

View Article and Find Full Text PDF

Background: Generalized lymphatic anomaly (GLA) is a rare congenital lymphatic malformation (LM) characterized by multiple infiltrating lymphangiomas in various tissues. Owing to its rarity, information on this disease is obtained mainly through case reports, leading to delayed diagnosis. In this study, we reported a case of generalized lymphatic anomaly in a pediatric patient manifesting as hemorrhagic pleural effusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!