A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quality by Design in continuous bioprocessing: Investigating the impact of critical process parameters of multi-column chromatography during steady-state and transient phases. | LitMetric

Given the complexities of continuous bioprocessing, it is critical to thoroughly investigate the process parameters unique to multi-column chromatography (MCC) and their potential impacts. However, existing studies have focused on either loading densities or residence time at steady states only, and their combined impact on critical quality attributes (CQAs) especially during transient phases were less known. In this study, we investigated the impact of critical process parameters during both steady-state and transient phases (start-up, close-down, and intermediate perturbation) through full factorial design. Our findings revealed that MCC operation with static control results in a maximum delta UV variation (breakthrough percentage from 1 loading column) of 30 % between the start-up phase and steady state. Additionally, eluate concentration showed a slight increase (with a maximum difference of 1.9 mg/mL, equivalent to 25 % deviation) when transitioning from the start-up phase to steady state but significantly decreased (with a maximum difference of 8.2 mg/mL, equivalent to 93 % deviation) when shifting from steady state to the close-down phase. The monomer purity during start-up and steady-state phases remained above 97 % while the close-down phase eluate purity ranged from 57 % to 98 %, depending on the operating conditions. Nevertheless, the variation in product quality can be potentially mitigated by product diversion or pooling with high-purity eluates from steady-state, highlighting the robustness of MCC operation in maintaining consistent product quality. Therefore, our study underscores the critical need to comprehensively understand the process dynamics of MCC operation at both steady state and transient phases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2024.465649DOI Listing

Publication Analysis

Top Keywords

transient phases
16
steady state
16
impact critical
12
process parameters
12
mcc operation
12
continuous bioprocessing
8
critical process
8
multi-column chromatography
8
steady-state transient
8
start-up phase
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!