A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Meta-analysis of MitraClip and PASCAL for transcatheter mitral edge-to-edge repair. | LitMetric

Meta-analysis of MitraClip and PASCAL for transcatheter mitral edge-to-edge repair.

J Cardiothorac Surg

Department of Internal Medicine II, Städtisches Klinikum Solingen, Solingen, Germany.

Published: January 2025

Background: Despite the promising results of both MitraClip and PASCAL systems for the treatment of mitral regurgitation (MR), there is limited data on the comparison of both systems regarding their safety and efficacy. We aim to compare both systems for MR.

Materials And Methods: Five databases were searched until October 2024. Original studies were only included and critically appraised using an adapted version of the Newcastle-Ottawa scale for observational cohort studies and the Cochrane risk of bias tool for randomized controlled trials. The risk ratio (RR) and mean difference (MD) with their corresponding 95% confidence interval (95% CI).

Results: From the database search, we identified 197 studies, of which eight studies comprising 1,612 patients who underwent transcatheter edge-to-edge repair with either MitraClip or PASCAL were included in this meta-analysis. The statistical analysis revealed no significant difference between the two devices in achieving a two-grade reduction in MR severity (RR = 0.95; 95% CI: [0.86, 1.04]; p = 0.28), one-grade reduction (RR = 1.17; 95% CI: [0.92, 1.49]; p = 0.19), or in cases with no improvement (RR = 1.23; 95% CI: [0.79, 1.90]; p = 0.36). Additionally, there were no significant differences between PASCAL and MitraClip regarding procedure time, procedural success, reinterventions, or all-cause mortality. However, PASCAL trended towards better residual MR reduction, although this was accompanied by moderate heterogeneity. Both devices demonstrated comparable safety profiles and were effective in reducing MR and improving cardiac function.

Conclusion: MitraClip and PASCAL devices showed comparable safety profiles and procedural success rates. However, the analysis did not reveal a statistically significant difference between the two devices in reducing the severity of MR.

Download full-text PDF

Source
http://dx.doi.org/10.1186/s13019-024-03218-4DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11697868PMC

Publication Analysis

Top Keywords

mitraclip pascal
16
edge-to-edge repair
8
difference devices
8
procedural success
8
comparable safety
8
safety profiles
8
pascal
6
95%
5
meta-analysis mitraclip
4
pascal transcatheter
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!