A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Method development and validation on RP-HPLC method for estimation of xanthohumol in nanostructured lipid carriers drug delivery systems. | LitMetric

Method development and validation on RP-HPLC method for estimation of xanthohumol in nanostructured lipid carriers drug delivery systems.

J Chromatogr B Analyt Technol Biomed Life Sci

School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, India; Faculty of Health, Australian Research Centre in Complementary and Integrative Medicine, University of Technology Sydney, Ultimo, NSW 2007, Australia. Electronic address:

Published: December 2024

Xanthohumol(Xn) is isolated from female inflorescences of Humulus lupulus. It has been discovered that Xn and its formulation are useful in the treatment of cancer. As this bioactive compound has medicinal importance, hence, a novel, precise, and sensitive HPLC method should be developed. In the present study, an RP-HPLC method has been developed and validated as per ICH Q2(R1) guidelines using column C18 having particle size 5 µm and dimension 250 × 4.6 mm. The detection wavelength (λ) used was 370 nm. The mobile phase consisted of a combination of HPLC grade Methanol and HPLC grade water buffer at a ratio of 95:5 v/v, with a flow rate of 1.0 mL/min. The total run time was 10 min with Xn retention time (Rt) at 4.5 min. The calibration plot was found linear in the range 2-10 μg/mL. The recovery of 97.65 % indicated good accuracy of method. The method's precision is within 2 % of acceptable limits. LOD and LOQ values of 0.85 and 2.6 μg/mL indicated good sensitivity of method. The uniqueness of the research work is relying on achieving peak of Xn at lesser retention time as compared to existing methods. Further the results of specificity studies revealed absence of any interference of Xn peak with the excipients used in the nanostructured lipid carriers (NLCs). Overall, the study provided an accurate, precise, sensitive and specific method to quantify Xn in bulk and NLCs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2024.124437DOI Listing

Publication Analysis

Top Keywords

rp-hplc method
8
nanostructured lipid
8
lipid carriers
8
precise sensitive
8
method developed
8
hplc grade
8
retention time
8
indicated good
8
method
7
method development
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!