Quantitative 3-T Multiparametric MRI Parameters as Predictors of Aggressive Prostate Cancer.

Radiol Imaging Cancer

From the Departments of Radiological Sciences (D.H.S.K., I.S., V.M., W.H., K.H.S., D.S.L., S.S.R.), Medicine Statistics Core (T.G.), Pathology (A.S.), and Urology (R.E.R., S.S.R.), David Geffen School of Medicine at UCLA, 885 Tiverton Dr, Los Angeles, CA 90095.

Published: January 2025

Purpose To determine which quantitative 3-T multiparametric MRI (mpMRI) parameters correlate with and help predict the presence of aggressive large cribriform pattern (LCP) and intraductal carcinoma (IDC) prostate cancer (PCa) at whole-mount histopathology (WMHP). Materials and Methods This retrospective study included 130 patients (mean age ± SD, 62.6 years ± 7.2; 100% male) with 141 PCa lesions who underwent preoperative prostate 3-T mpMRI, radical prostatectomy, and WMHP between January 2019 and December 2022. Lesions at WMHP were matched to 3-T mpMRI lesions with American College of Radiology Prostate Imaging Reporting and Data System version 2.1 scores of at least 3 or higher, and the following parameters were derived: apparent diffusion coefficient (ADC), volume transfer constant, rate constant, and initial area under the curve (iAUC). Each lesion was categorized into three subcohorts with increasing aggressiveness: LCP negative and IDC negative (subcohort 1), LCP positive and IDC negative (subcohort 2), and LCP positive and IDC negative (subcohort 3). Analysis of variance was performed to assess differences, Jonckheere test was performed to establish trends, and a classification and regression tree (CART) was used to establish a prediction model. Results Of the 141 total lesions, there were 41 (29.1%), 49 (34.8%), and 51 (36.2%) lesions in subcohorts 1, 2, and 3, with mean ADCs of 892 × 10 mm/sec ± 20, 826 × 10 mm/sec ± 209, and 763 × 10 mm/sec ± 163 ( = .007) and mean iAUCs of 5.4 mmol/L/sec ± 2.5, 6.7 mmol/L/sec ± 3.0, and 6.9 mmol/L/sec ± 3.5 ( = .04), respectively. ADC was negatively correlated ( = .004), and rate constant and iAUC were positively correlated ( = .048 and = .04, respectively) with increasing histologic PCa aggressiveness. The CART model correctly allocated 39.0%, 24.5%, and 84.3% of PCa lesions to subcohorts 1, 2, and 3, respectively. Conclusion Quantitative 3-T mpMRI parameters significantly correlated with and helped predict aggressive LCP and IDC PCa at WMHP. Prostate, MRI, Pathology © RSNA, 2025.

Download full-text PDF

Source
http://dx.doi.org/10.1148/rycan.240011DOI Listing

Publication Analysis

Top Keywords

quantitative 3-t
12
3-t mpmri
12
idc negative
12
negative subcohort
12
3-t multiparametric
8
multiparametric mri
8
prostate cancer
8
mpmri parameters
8
pca lesions
8
rate constant
8

Similar Publications

Quantitative 3-T Multiparametric MRI Parameters as Predictors of Aggressive Prostate Cancer.

Radiol Imaging Cancer

January 2025

From the Departments of Radiological Sciences (D.H.S.K., I.S., V.M., W.H., K.H.S., D.S.L., S.S.R.), Medicine Statistics Core (T.G.), Pathology (A.S.), and Urology (R.E.R., S.S.R.), David Geffen School of Medicine at UCLA, 885 Tiverton Dr, Los Angeles, CA 90095.

Purpose To determine which quantitative 3-T multiparametric MRI (mpMRI) parameters correlate with and help predict the presence of aggressive large cribriform pattern (LCP) and intraductal carcinoma (IDC) prostate cancer (PCa) at whole-mount histopathology (WMHP). Materials and Methods This retrospective study included 130 patients (mean age ± SD, 62.6 years ± 7.

View Article and Find Full Text PDF

Background: Post-traumatic osteoarthritis (PTOA) often follows anterior cruciate ligament reconstruction (ACLR), leading to early cartilage degradation. Change in mean T fails to capture subject-specific spatial-temporal variations, highlighting the need for robust quantitative methods for early PTOA detection and monitoring.

Purpose/hypothesis: Develop and apply 3D T cluster analysis to ACLR and healthy knees over 2.

View Article and Find Full Text PDF

Clinical validation of a prognostic preclinical magnetic resonance imaging biomarker for radiotherapy outcome in head-and-neck cancer.

Radiother Oncol

December 2024

Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Tübingen, Germany; German Cancer Consortium (DKTK), partner site Tübingen, and German Cancer Research Center (DKFZ), Heidelberg, Germany; Cluster of Excellence "Machine Learning", University of Tübingen, Tübingen, Germany. Electronic address:

Purpose: To retrain a model based on a previously identified prognostic imaging biomarker using apparent diffusion coefficient (ADC) values from diffusion-weighted magnetic resonance imaging (DW-MRI) in a preclinical setting and validate the model using clinical DW-MRI data of patients with locally advanced head-and-neck cancer (HNC) acquired before radiochemotherapy.

Material And Methods: A total of 31 HNC patients underwent T2-weighted and DW-MRI using 3 T MRI before radiochemotherapy (35 x 2 Gy). Gross tumor volumes (GTV) were delineated based on T2-weighted and b500 images.

View Article and Find Full Text PDF

Background: Three-dimensional MR fingerprinting (3D-MRF) has been increasingly used to assess cartilage degeneration, particularly in the knee joint, by looking into multiple relaxation parameters. A comparable 3D-MRF approach can be adapted to assess cartilage degeneration for the hip joint, with changes to accommodate specific challenges of hip joint imaging.

Purpose: To demonstrate the feasibility and repeatability of 3D-MRF in the bilateral hip jointly we map proton density (PD), T, T, T, and ∆B in clinically feasible scan times.

View Article and Find Full Text PDF

Myelin is essential in the nervous system of mammals. As the location and degree of myelin loss can reflect varied pathophysiological status, noninvasive measurement of myelin is of high importance. The magnetic resonance imaging (MRI) technique of myelin water fraction (MWF) derived from multi-echo gradient echo (MGRE) sequence is a promising tool for the quantification of myelin content due to the low specific absorption rate (SAR) compared with the spin-echo sequence, time efficiency, and wide availability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!