Aim: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.

Settings And Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.

Materials And Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone. The dies were divided into two groups: Group-A (PEEK) copings and Group-B (zirconia) copings. All copings were fabricated using a CAD/CAM system. Vertical marginal accuracy was assessed with a stereomicroscope and image analysis software at ×20 magnification. The marginal gaP values were subjected to a student (independent) t-test for statistical analysis.

Statistical Analysis Used: The statistical analysis involved a student (independent) t-test to compare the marginal gaP values between Group A (PEEK) and Group B (zirconia).

Results: The mean marginal discrepancy for Group A (PEEK) and Group B (zirconia) was 92.84 μm ± 3.48 μm and 63.12 μm ± 31.47 μm, respectively. A statistically significant variation (t = 3.635, P = 0.001) between the groups was observed, indicating better marginal accuracy with zirconia copings compared to PEEK copings.

Conclusion: Both PEEK and zirconia copings demonstrated vertical marginal discrepancies within the clinically acceptable limit of <120 μm. However, zirconia copings exhibited superior marginal accuracy in this in vitro study.

Download full-text PDF

Source
http://dx.doi.org/10.4103/jips.jips_8_24DOI Listing

Publication Analysis

Top Keywords

zirconia copings
20
marginal accuracy
16
copings fabricated
12
accuracy polyetheretherketone
8
fabricated computer-aided
8
computer-aided design/computer-aided
8
design/computer-aided manufacturing
8
compare marginal
8
peek zirconia
8
stone dies
8

Similar Publications

Aim: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.

Settings And Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.

Materials And Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone.

View Article and Find Full Text PDF

Introduction: The marginal fit of dental restorations is essential for longevity and effectiveness of fixed prostheses, particularly single-unit crowns. Direct digital scanning offers significant advantages over indirect methods, providing a non-invasive, accurate, and reproducible means to evaluate marginal fit. This study aimed to assess the marginal fit of single-unit copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia, direct metal laser sintering (DMLS), and porcelain-fused-to-metal (PFM) utilizing direct three-dimensional (3D) scanning.

View Article and Find Full Text PDF

Tensile Bond Strength, Fit Accuracy and Failure Types of Zirconia and Cast Gold Root Copings for Overdentures.

Eur J Prosthodont Restor Dent

November 2024

Center for Dental Medicine, Clinic of Masticatory Dysfunction and Dental Biomaterials, University of Zurich, Zurich, Switzerland.

Aim: To compare the tensile strength, dislodgement forces, marginal gap and failure types between digitally fabricated zirconia root copings and conventionally manufactured cast gold root copings.

Methods: Extracted human teeth (N=30) were prepared for the root copings and randomly divided into 2 groups: (1)zirconia root copings(ZC) and gold root copings(GC). The specimens were tested for tensile bond strength and dislodgement forces in a universal testing machine and the types of the coping failures modes were analyzed.

View Article and Find Full Text PDF

Objective: The purpose of this study was to assess the accuracy of full coverage crowns produced by two manufacturing methods: additive 3D printing and subtractive milling utilizing three different predefined cement spaces.

Materials And Methods: Six groups were allocated based on the manufacturing method and the predefined cement space: printed wax with a 20 µm space (PW1); printed wax with a 50 µm space (PW2); printed wax with a 100 µm space (PW3); milled wax with a 20 µm cement space (MW1); milled wax with a 50 µm cement space (MW2); milled wax with a 100 µm cement space (MW3); milled zirconia coping with a 20 µm cement space (MZ1); milled zirconia coping with a 50 µm cement space (MZ2); milled zirconia with a 100 µm cement space (MZ3). All fabricated specimens were scanned using an Identica Blue 3D scanner and saved as standard tessellation language (STL) files.

View Article and Find Full Text PDF

Aging and Fracture Tests on Differently Veneered Partially Stabilized Zirconia Anterior Crowns.

Int J Dent

October 2024

Department of Prosthodontics, University Clinic Heidelberg, University of Heidelberg, Heidelberg, Germany.

To evaluate the fracture resistance of veneered incisor crowns made from highly translucent zirconia frameworks. Ninety-six all-ceramic single crowns were based on either a coping with minimum wall thickness or a cutback framework fabricated from highly translucent zirconia (5Y-PSZ). Each one-third of the specimens was finalized with different veneering ceramics using standardizations and glaze firing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!