A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative evaluation of pattern and distribution of stresses in single- and double-implant overdenture using ball-ring, positioner, and magnet-keeper attachment under different loading conditions: A finite element analysis. | LitMetric

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture. Implants of size 12 mm by 3.4 mm body diameter (Implantium, Dentium, Korea) were used along with ball O-ring, positioner, and magnet attachment system for constructing single and double implant overdenture. FEA models were processed defining geometry. Six models were formulated, namely, three models of central single implant and three for double implant overdenture using ball O-ring attachment, positioner attachment, and magnet attachment named B1, P1, M1, B2, P2, and M2, respectively. The FEM analysis was done using ANSYS workbench 16.0. A load of around 100N was applied bilaterally in the first molar regions, anteriorly between the two central incisors, and unilaterally on the right first molar region. Stresses were calculated according to the Von Mises stresses scale. Stress magnitude and patterns were analyzed and interpreted accordingly.

Statistical Analysis Used: Stress patterns and maximum principal stress were described.

Results: FEM analysis revealed that stress concentration in the B1 model was the highest. Anterior loading produced maximum stress followed by unilateral and lastly bilateral loading. In the bone, stress concentration was the highest in the crestal bone region (3-18 MPa). Mucosa showed the least amount of stress in all models (1.3-3 MPa). Stress patterns in dentures were symmetric with concentration on the mid-lingual and molar premolar area (3-18 MPa). Implants showed stress concentration near the collar and the internal connection region (7.5-24 MPa). Maximum stresses were around the head of prosthetic abutments (10.5-24 MPa). The stress concentration in the ball head was typically located in the abutment neck. In positioner attachment, stress was located in the inner open end area (11-20.1 MPa). For the keeper, stresses were at its base and stress patterns extended into the body (10.5-17.7 MPa). Less stress magnitude was seen for all models on bilateral loading (10.5-15 MPa).

Conclusion: Magnet and positioner attachments have a more favorable stress distribution in both single and double implant-retained overdentures. Bilateral loading conditions are more favorable for uniform stress patterns.

Download full-text PDF

Source
http://dx.doi.org/10.4103/jips.jips_179_24DOI Listing

Publication Analysis

Top Keywords

stress
16
stress patterns
16
stress concentration
16
finite element
12
single double
12
bilateral loading
12
mpa stress
12
loading conditions
8
element analysis
8
stress distribution
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!