Background: Predictors of difficult fiberscopic intubation have not been fully elucidated. This study focused on identifying radiographic predictors of difficult fiberscopic intubation during general anesthesia in patients with a cervical collar.

Methods: This retrospective study included unconscious patients who underwent orotracheal intubation using a flexible fiberscope while wearing a cervical collar to simulate a difficult airway. Easy fiberscopic intubation was defined as successful fiberscopic intubation within 120 seconds on the first attempt without desaturation below 90%. The patients were divided into easy (n=133) and difficult (n=24) fiberscopic intubation groups. Demographic, mask ventilation-related, upper airway-related, and radiographic variables measured on sagittal images of preoperative cervical x-ray and magnetic resonance imaging were analyzed.

Results: The difficult fiberscopic intubation group had a smaller oral cavity area (2.1 [1.2-2.5] vs. 2.9 [2.1-3.7] cm2, P<0.001), higher tongue area divided by oral cavity area (9.3 [6.5-13.3] vs. 6.4 [4.6-8.3], P<0.001), smaller epiglottis angle (33±10° vs. 37±8°, P=0.02), and longer skin-glottis distance (1.3 [1.1-1.6] vs. 1.1 [1.0-1.3] cm, P=0.004). Tongue area/oral cavity area (odds ratio per 1 [95% CI]: 1.24 [1.09-1.40]) and skin-glottis distance (odds ratio per 1 cm [95% CI]: 13.0 [2.69-62.4]) were independently associated with the difficulty in fiberscopic intubation.

Conclusions: High tongue area/oral cavity area and long skin-glottis distance were predictive of difficult fiberscopic intubation during general anesthesia in patients with a cervical collar.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ANA.0000000000001019DOI Listing

Publication Analysis

Top Keywords

fiberscopic intubation
28
difficult fiberscopic
16
predictors difficult
12
radiographic predictors
8
intubation
8
intubation general
8
general anesthesia
8
anesthesia patients
8
patients cervical
8
cervical collar
8

Similar Publications

Background: Predictors of difficult fiberscopic intubation have not been fully elucidated. This study focused on identifying radiographic predictors of difficult fiberscopic intubation during general anesthesia in patients with a cervical collar.

Methods: This retrospective study included unconscious patients who underwent orotracheal intubation using a flexible fiberscope while wearing a cervical collar to simulate a difficult airway.

View Article and Find Full Text PDF

We present a case of an infant patient with Robin sequence (Pierre Robin sequence; PRS) who underwent general anesthesia for a glossopexy procedure. Pediatric patients with PRS are prone to upper airway obstruction during general anesthesia induction and intubation difficulties due to micrognathia and glossoptosis. In this case, we facilitated mask ventilation by inserting a nasopharyngeal airway before induction and successfully intubated the patient using a 2-person technique that combined the use of a video laryngoscope and a flexible fiber-optic scope.

View Article and Find Full Text PDF

Obstetric difficult airway management has emerged as a critical safety issue, and unsuccessful intubation can lead to morbidity and mortality. A literature review of difficult and failed obstetric intubations from the 1970s to 2015 shows that the incidence of failed intubation is unchanged, remaining at one per 390 anesthetics. Our obstetric case report highlights an obstetric difficult airway secondary to limited mouth opening; rescue of the airway with an i-gel®; and establishment of a definitive airway with the aid of an Aintree intubation catheter and flexible fiberoptic scope-guided intubation through the i-gel®, a second-generation supraglottic airway.

View Article and Find Full Text PDF

Comparison of the clinical performance of the Ambu®AuraGain™ laryngeal mask in children undergoing surgery in the supine and prone position - A prospective, non-inferiority clinical trial.

J Clin Anesth

December 2024

Department of Anesthesiology and Pain Medicine, Severance Hospital, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodamungu, Seoul 03722, Republic of Korea. Electronic address:

Article Synopsis
  • This study evaluated the effectiveness of the Ambu®AuraGain™, a second-generation supraglottic airway (SGA), in children undergoing surgery in both prone and supine positions.
  • The research involved 126 children aged 2-12 years, measuring oropharyngeal leak pressure (OLP) after positioning and noting any airway-related issues.
  • Results showed that OLP in the prone position was not inferior to the supine position, although more airway maneuvers were needed for the prone position, suggesting it may be slightly more challenging.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?