A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A fully integrated microfluidic cartridge for rapid and ultrasensitive nucleic acid detection from oropharyngeal swabs. | LitMetric

Rapid and accurate molecular diagnostics are crucial for preventing the global spread of emerging infectious diseases. However, the current gold standard for nucleic acid detection, reverse transcription polymerase chain reaction (RT-PCR), relies heavily on traditional magnetic beads or silica membranes for nucleic acid extraction, resulting in several limitations, including time-consuming processes, the need for trained personnel, and complex equipment. Therefore, there is an urgent need for fully integrated nucleic acid detection technologies that are simple to operate, rapid, and highly sensitive to meet unmet clinical needs. In this study, we developed a novel, integrated microfluidic cartridge featuring a unique needle-plug/piston microvalve, which enables stable long-term reagent storage and flexible liquid handling for on-site nucleic acid analysis. Coupled with tetra-primer recombinase polymerase amplification (tp-RPA), we achieved highly sensitive nucleic acid detection with a remarkable limit of detection of 20 copies per mL (0.02 copies per μL) and a short turnaround time of less than 30 minutes. To validate this assay, we tested 48 oropharyngeal swab samples. The positive detection rate reached 64.58% (31/48), significantly exceeding the approximately 50% positive detection rate of the traditional RT-PCR method. Furthermore, our assay demonstrated a 100% concordance rate with RT-PCR in detecting positive samples. Thus, we believe our microfluidic nucleic acid analysis system represents a promising approach for enabling rapid and ultrasensitive nucleic acid detection of pathogenic microorganisms in resource-limited settings and low-income areas.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4lc00770kDOI Listing

Publication Analysis

Top Keywords

nucleic acid
32
acid detection
20
fully integrated
8
integrated microfluidic
8
microfluidic cartridge
8
rapid ultrasensitive
8
nucleic
8
ultrasensitive nucleic
8
acid
8
detection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!