A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validated LC-MS/MS Method for the Determination of Paxalisib on Mouse Dried Blood Spots: An Application to Pharmacokinetic Study in Mice. | LitMetric

Validated LC-MS/MS Method for the Determination of Paxalisib on Mouse Dried Blood Spots: An Application to Pharmacokinetic Study in Mice.

Biomed Chromatogr

Department of Pharmaceutical Analysis, School of Pharmacy, Anurag University, Medchal-Malkajgiri, Hyderabad, Telangana, India.

Published: February 2025

Paxalisib is a dual PI3K/mTOR inhibitor, being used in advanced cancer treatment. In this research, we report a validated LC-MS/MS method for quantifying paxalisib from mouse dried blood spot (DBS). We validated the method in-line with the FDA guidelines. Liquid-liquid extraction technique was used to extract paxalisib from the DBS discs. We used a Chromolith RP-18 end cap (100 × 4.6 mm) column and isocratic mobile phase for the chromatographic separation of paxalisib and the internal standard (IS, dasatinib). The flow was 0.80 mL/min. In the optimized chromatographic conditions, the retention of paxalisib and the IS was ~2.13 and 2.06 min, respectively. Each injection total run time was 2.50 min. The MS/MS ion transitions monitored were m/z 383.2 → 309.1 and 488.1 → 410.1 for paxalisib and the IS, respectively. We have used a broad calibration range (1.24-3762 ng/mL) with a determination coefficient (r) of 0.995. All the validation parameters assessed met the acceptance criteria, and hematocrit had no effect on DBS Paxalisib concentrations. We have used the validated method to derive the intravenous and oral pharmacokinetic parameters by quantifying paxalisib in mouse blood and correlated with mice pharmacokinetic data.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.6071DOI Listing

Publication Analysis

Top Keywords

paxalisib mouse
12
paxalisib
9
validated lc-ms/ms
8
lc-ms/ms method
8
mouse dried
8
dried blood
8
quantifying paxalisib
8
validated method
8
validated
4
method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!