A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Relationship between skin temperature and blood flow during exposure to radio frequency energy: implications for device development. | LitMetric

Relationship between skin temperature and blood flow during exposure to radio frequency energy: implications for device development.

BMC Biomed Eng

William B. Burnsed Jr. Department of Mechanical, Aerospace, and Biomedical Engineering, University of South Alabama, 150 Student Services Drive, Mobile, AL, 36688, USA.

Published: January 2025

Background: The ST response to high frequency EM heating may give an indication of rate of BF in underlying tissue. This novel method, which we have termed REFLO (Rapid Electromagnetic Flow) has potential for applications such as detection of PAD. The method utilizes the relationship between blood flow rate and tissue temperature increase during exposure to radio frequency (RF) energy. We are developing an REFLO device to screen for peripheral artery disease (PAD). PAD is characterized by impaired blood flow to the legs, as reflected in the skin microcirculation. The REFLO system incorporates a radio frequency transmitter and a compact transducer housing a micropatch antenna and an infrared (IR) temperature sensor. At high RF frequencies (> 6 GHz) tissue heating is confined to the skin, such that an indication of blood flow may be inferred from the temperature response to controlled heating. The objective of this study is to determine the extent to which the magnitude and depth of heating as well as device sensitivity are functions of (i) RF frequency and (ii) thickness of the dermal tissue layer.

Results: Results show that it is feasible to measure blood flow rate with REFLO technology. Surface temperature increases were found to be more dependent upon the magnitude of power absorption than location of absorption within the skin. While surface temperature response does depend upon radio wave frequency and thickness of the dermis layer, such dependencies are mild. Sensitivity to blood flow rate was found to be proportional to the magnitude of absorbed power.

Conclusion: Results show that it is feasible to discriminate between blood flow rates using REFLO technology at frequencies within the 10-94 GHz range. All frequencies analyzed produced similar levels of sensitivity to blood flow rate despite significant differences in penetration depth. These results are being used in the development of a preclinical prototype for quick and easy detection of asymptomatic PAD in humans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11697893PMC
http://dx.doi.org/10.1186/s42490-024-00087-9DOI Listing

Publication Analysis

Top Keywords

blood flow
32
flow rate
16
radio frequency
12
flow
9
blood
8
exposure radio
8
frequency energy
8
temperature response
8
frequency thickness
8
reflo technology
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!