A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users. Therefore, the customized topographic control of each manufactured MIOL model, along with the advancement of optical simulation routines, is increasingly necessary to provide users with optimized performance of these implanted optics, as well as predictable and realistic expectations of their future vision with these solutions. In this manuscript, experimental results of the reconstruction of different smooth and highly edged diffractive profiles from a pair of commercially available MIOLs are presented. Besides, a study evaluating the convergence and robustness of the proposed iterative phase-retrieval routine based on a modified classical Gerchberg-Saxton algorithm is performed. These results provide experimental validation of the proposed technique for accurately measuring the optical profiles of MIOLs.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41598-024-84363-7DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11696758PMC

Publication Analysis

Top Keywords

intraocular lenses
8
non-contact lensless
4
lensless holographic
4
holographic reconstruction
4
diffractive
4
reconstruction diffractive
4
diffractive intraocular
4
lenses profiles
4
profiles lensless
4
lensless compact
4

Similar Publications

Photic phenomena are more pronounced in presbyopia-corrected than in monofocal intraocular lens (IOL), causing dissatisfaction after cataract surgery. Photic Phenomena Test (PPT) quantifies photic phenomena in eyes with two types of presbyopia-corrected IOL. We examined the relationship between preoperative eye shape and pupil diameter.

View Article and Find Full Text PDF

A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users.

View Article and Find Full Text PDF

[Cataracts extraction combined with multifocal intraocular lens optic implantation in Berger space in school-age children with cataracts].

Zhonghua Yan Ke Za Zhi

January 2025

Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Key Laboratory of Eye Diseases, School of Ophthalmology, Shandong First Medical University, Qingdao266071, China.

To evaluate the safety and efficacy of cataract extraction combined with multifocal intraocular lens (IOL) optic implantation in Berger space in school-age children with cataracts. It was a prospective study. The clinical data of school-age children with cataract who underwent cataract extraction combined with multifocal IOL implantation at Qingdao Eye Hospital of Shandong First Medical University from January 2019 to June 2023 were collected.

View Article and Find Full Text PDF

Background: To evaluate the ocular biometry agreement and prediction of postoperative refractive outcomes obtained using two swept-source optical coherence tomography (SS-OCT) biometers: Anterion (Heidelberg Engineering, Heidelberg, Germany) and Argos (Alcon, Fort Worth, TX, USA).

Methods: Ambispective analysis was conducted on 105 eyes at the Samsung Medical Center, Seoul, Republic of Korea, between June 2021 and March 2022. Biometric values were assessed using both devices before cataract surgery.

View Article and Find Full Text PDF

Background: The new patient cataract and lens ophthalmic questionnaire (CLOQ) determines subjective patient satisfaction before and after cataract surgery according to item response theory (IRT).

Methods: A total of 317 patients with bilateral cataract surgery and implantation of different intraocular lens (IOL) types were included. The questionnaire (37 questions) is divided into questions on visual acuity-relevant quality of life (VRQoL), quality of vision (QoV), spectacle dependence, and general satisfaction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!