Use of refractive aids among adults in a general population.

Sci Rep

Department of Clinical Medicine, Aarhus University, Aarhus N, DK-8200, Denmark.

Published: January 2025

Spectacles and contact lenses are important for conducting a normal life in a large part of the general population. The purpose of this study was to estimate the use of these refractive aids in a normal adult population, and to identify characteristics of persons who should be targeted in order to improve uncorrected refraction. In the FORSYN study, 10,350 citizens representative for the adult Danish population were invited for a non-cycloplegic eye examination. The examination was completed in 3,384 persons, and the data were adjusted to represent the frequencies in the originally invited population on the basis of age, sex and socio-economic factors. The frequencies were projected to estimates of absolute numbers in the total adult Danish population. Refractive aids were used by 72.6%, 95% CI: 71.7-73.5% of the adult population. Distance correction was used by 55.7% (95% CI: 54.8-56.7%), contact lenses alone or alternating with spectacles by 11.2% (95% CI: 10.6-11.8%) and reading glasses by 18.8% (95% CI: 18.0-19.5%). Uncorrected refractive error resulted in a reduction in distance visual acuity of 2.99 ETDRS letters per diopter of hyperopia and of 10.3 ETDRS letters per diopter myopia (p < 0.0001 for both regressions). Uncorrected refractive error reduced distance visual acuity significantly in persons using single vision spectacle lenses and progressive addition spectacle lenses that had been prescribed more than 3 years previously. Refractive aids were used in approximately 72% of the population and should be checked when more than 3 years have passed since the last visit with a dispensing optometrist.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41598-024-84045-4DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11696050PMC

Publication Analysis

Top Keywords

refractive aids
12
general population
8
contact lenses
8
adult population
8
adult danish
8
danish population
8
etdrs letters
8
letters diopter
8
population
7
refractive
4

Similar Publications

Use of refractive aids among adults in a general population.

Sci Rep

January 2025

Department of Clinical Medicine, Aarhus University, Aarhus N, DK-8200, Denmark.

Spectacles and contact lenses are important for conducting a normal life in a large part of the general population. The purpose of this study was to estimate the use of these refractive aids in a normal adult population, and to identify characteristics of persons who should be targeted in order to improve uncorrected refraction. In the FORSYN study, 10,350 citizens representative for the adult Danish population were invited for a non-cycloplegic eye examination.

View Article and Find Full Text PDF

Head-mounted devices (HMDs) are wearable electronic tools designed to augment the visual experience of low-vision patients who have a decrease in vision not improved by refractive correction. They do so by addressing various principles of visual enhancement, including magnification, illumination, increased field of view, and contrast sensitivity enhancement, among others. Since the introduction of the first HMD 3 decades ago, advancements in technology have made these devices more lightweight and practical for everyday use.

View Article and Find Full Text PDF
Article Synopsis
  • The paper introduces a novel metamaterial absorber design using a bent Y-shaped structure on an FR-4 substrate with copper, achieving over 90% absorption across a range of frequencies from L-band to K-band (3.728 GHz to 22.664 GHz).
  • Through simulations, it identifies eight resonant frequencies, highlighting the design's versatility for reducing electromagnetic radiation.
  • Additionally, the research discusses the implications of near-zero refractive index metamaterials and their potential for advanced wave control, emphasizing the absorber's polarization insensitivity and unique electromagnetic properties that challenge existing theories.
View Article and Find Full Text PDF

Antibody testing for virus aids diagnosis, promotes vaccination and development, and evaluates antibody treatment efficacy. Hence, it is essential to examine and monitor antibody levels for accurate disease diagnosis and prevention. Lateral Flow Immunoassay (LFIA) is a technique that is known for its simplicity and speed, making it a popular choice for immediate detection.

View Article and Find Full Text PDF

Purpose: To evaluate the visual outcomes of keratorefractive lenticule extraction using a new version of a femtosecond laser platform with semi-automated cyclotorsion compensation in comparison to the previous generation without cyclotorsion control.

Methods: This was an ambispective study of consecutive eyes treated by SMILE with the VisuMax and VISUMAX 800 femtosecond lasers at the Uma Eye clinic, Chennai, India between June 2022 and July 2023. Inclusion criteria were myopia up to -10 D and astigmatism between 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!