The hippocampal CA3 subregion is a densely connected recurrent circuit that supports memory by generating and storing sequential neuronal activity patterns that reflect recent experience. While theta phase precession is thought to be critical for generating sequential activity during memory encoding, the circuit mechanisms that support this computation across hippocampal subregions are unknown. By analyzing CA3 network activity in the absence of each of its theta-modulated external excitatory inputs, we show necessary and unique contributions of the dentate gyrus (DG) and the medial entorhinal cortex (MEC) to phase precession. DG inputs are essential for preferential spiking of CA3 cells during late theta phases and for organizing the temporal order of neuronal firing, while MEC inputs sharpen the temporal precision throughout the theta cycle. A computational model that accounts for empirical findings suggests that the unique contribution of DG inputs to theta-related spike timing is supported by targeting precisely timed inhibitory oscillations. Our results thus identify a novel and unique functional role of the DG for sequence coding in the CA3 circuit.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41467-024-54943-2DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11696047PMC

Publication Analysis

Top Keywords

phase precession
12
dentate gyrus
8
gyrus medial
8
medial entorhinal
8
entorhinal cortex
8
hippocampal ca3
8
inputs
5
ca3
5
distinct roles
4
roles dentate
4

Similar Publications

The hippocampal CA3 subregion is a densely connected recurrent circuit that supports memory by generating and storing sequential neuronal activity patterns that reflect recent experience. While theta phase precession is thought to be critical for generating sequential activity during memory encoding, the circuit mechanisms that support this computation across hippocampal subregions are unknown. By analyzing CA3 network activity in the absence of each of its theta-modulated external excitatory inputs, we show necessary and unique contributions of the dentate gyrus (DG) and the medial entorhinal cortex (MEC) to phase precession.

View Article and Find Full Text PDF

Artifacts at Cardiac MRI: Imaging Appearances and Solutions.

Radiographics

January 2025

From the Department of Radiology, Cardiovascular Imaging, Mayo Clinic, 200 1st St SW, Rochester, MN 559905 (P.S.R., P.A.A.); Department of Radiology, Division of Cardiothoracic Imaging, Jefferson University Hospitals, Philadelphia, Pa (B.S.); Department of Radiology, Baylor Health System, Dallas, Tex (P.R.); Department of Diagnostic Radiology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong SAR (M.Y.N.); and Department of Diagnostic Radiology, Cleveland Clinic, Cleveland, Ohio (M.A.B.).

Cardiac MRI (CMR) is an important imaging modality in the evaluation of cardiovascular diseases. CMR image acquisition is technically challenging, which in some circumstances is associated with artifacts, both general as well as sequence specific. Recognizing imaging artifacts, understanding their causes, and applying effective approaches for artifact mitigation are critical for successful CMR.

View Article and Find Full Text PDF

Electrophysiological Insights into Alzheimer's Disease: A Review of Human and Animal Studies.

Neurosci Biobehav Rev

December 2024

Interdisciplinary Neuroscience Program, University of Nevada, Las Vegas; Department of Psychology, University of Nevada, Las Vegas.

This review highlights the crucial role of neuroelectrophysiology in illuminating the mechanisms underlying Alzheimer's disease (AD) pathogenesis and progression, emphasizing its potential to inform the development of effective treatments. Electrophysiological techniques provide unparalleled precision in exploring the intricate networks affected by AD, offering insights into the synaptic dysfunction, network alterations, and oscillatory abnormalities that characterize the disease. We discuss a range of electrophysiological methods, from non-invasive clinical techniques like electroencephalography and magnetoencephalography to invasive recordings in animal models.

View Article and Find Full Text PDF

ORACLE: An analytical approach for T, T, proton density, and off-resonance mapping with phase-cycled balanced steady-state free precession.

Magn Reson Med

December 2024

Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Purpose: To develop and validate a novel analytical approach simplifying , , proton density (PD), and off-resonance quantifications from phase-cycled balanced steady-state free precession (bSSFP) data. Additionally, to introduce a method to correct aliasing effects in undersampled bSSFP profiles.

Theory And Methods: Off-resonant-encoded analytical parameter quantification using complex linearized equations (ORACLE) provides analytical solutions for bSSFP profiles.

View Article and Find Full Text PDF

The separation of diffraction effects from phase contrast is a major challenge for differential phase contrast (DPC) imaging in scanning transmission electron microscopy (STEM). The application of electron beam precession has previously been proven successful in homogenizing the direct beam and improving the imaging of both long-range electric and magnetic fields. However, magnetic STEM-DPC imaging performed in a low magnification (LM) STEM mode suffers from significant aberrations of the probe forming lens and the consequent impediment of small precession angles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!