A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cryogenic front-end circuit for capacitive sensing in superconducting gravimeters. | LitMetric

AI Article Synopsis

  • Capacitive sensors are essential for superconducting gravimeters due to their precision and minimal drift, prompting the development of a cryogenic front-end circuit to address parasitic capacitance issues.
  • The new circuit includes a noiseless superconducting transformer and a low-noise cryogenic preamplifier, significantly boosting the transfer coefficient and reducing displacement noise compared to circuits operating at room temperature.
  • Testing of the cryogenic front-end circuit with a superconducting gravimeter showed that the gravity data aligned well with theoretical models, indicating its effectiveness and stability over time.

Article Abstract

Capacitive sensors are commonly used in superconducting gravimeters due to their high resolution and low drift. This study developed a cryogenic front-end circuit for superconducting gravimeters to reduce the negative effects of parasitic capacitance on capacitive sensors. The front-end circuit comprises a noiseless superconducting transformer and a low-noise cryogenic preamplifier, both of which are positioned adjacent to the capacitive sensor probe. Compared with the front-end circuit operating at 300 K, the transfer coefficient of the front-end circuit increases from 131 to 1070 V/m, and the equivalent displacement noise reduces from 1.4 × 10-10 to 5.0 × 10-11 m/Hz1/2 within a frequency band from 10-3 to 1 Hz. The temperature coefficient of the cryogenic preamplifier is 0.3%/K, and the superconducting transformer's matching factor has adjusted as low as (2.4 ± 0.2) × 10-4. The cryogenic front-end circuit was finally applied to a superconducting gravimeter. The observed gravity data satisfactorily fit the theoretical tidal model, implying good long-term stability for the developed front-end circuit.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0236857DOI Listing

Publication Analysis

Top Keywords

front-end circuit
28
cryogenic front-end
12
superconducting gravimeters
12
capacitive sensors
8
cryogenic preamplifier
8
circuit
7
superconducting
6
front-end
6
cryogenic
5
capacitive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!