Background: Patients with transfemoral amputation experience socket-related problems and musculoskeletal overuse injuries, both of which are exacerbated by asymmetric joint loading and alignment. Bone-anchored limbs are a promising alternative to treat chronic socket-related problems by directly attaching the prosthesis to the residual limb through an osseointegrated implant; however, it remains unknown how changes in alignment facilitated through a bone-anchored limb relate to loading asymmetry.
Questions/purposes: What is the association between femur-pelvis alignment and hip loading asymmetry during walking before and 12 months after transfemoral bone-anchored limb implantation?
Methods: Between 2019 and 2022, we performed 66 bone-anchored limb implantation surgeries on 63 individuals with chronic socket-related problems. Of those, we considered those with unilateral transfemoral amputation as potentially eligible for this study. Based on that, 67% (42 of 63) were eligible, a further 55% (23 of 42) were excluded because they had incomplete datasets either at baseline (such as an inability to ambulate with a socket prosthesis) or did not complete the 12-month follow-up data collection. This resulted in 19 participants being included in this retrospective longitudinal analysis (9 males and 10 females, mean ± age 51 ± 11 years, mean BMI 28 ± 4 kg/m2). As part of standard clinical care, hip-to-ankle radiographs and motion capture data during overground walking were collected at two timepoints: 2 days before (preimplantation) and 12 months after bone-anchored limb implantation (postimplantation). Femur-pelvis skeletal alignment was measured from the radiographs (femoral abduction angle, residual femur length ratio, and pelvic obliquity). Symmetry indices of hip internal hip moment impulses (flexion/extension, abduction/adduction, internal/external rotation) were calculated from the motion capture data. Differences in alignment and internal joint moment impulse symmetry indices were compared across timepoints using paired t-tests with self-selecting walking speed as a covariate. Associations between skeletal alignment and hip moment impulse symmetry indices were computed at both timepoints using Spearman rank correlation with 5000 bootstrapped resamples.
Results: Twelve months after bone-anchored limb implantation, a comparison of preimplantation and postimplantation measurements showed reductions in the femoral abduction angle (-8° ± 10° versus 3° ± 4°, mean difference 11° [95% confidence interval (CI) 7° to 16°]; p < 0.001) and the residual femur length ratio (57% ± 15% versus 48% ± 11%, mean difference -9% [95% CI -12% to -5%]; p < 0.001). Additionally, a comparison of preimplantation and postimplantation calculations showed that the internal hip moment symmetry was improved in the sagittal and frontal planes (flexion symmetry index: 30 ± 23 versus 11 ± 19, mean symmetry index difference -19 [95% CI -31 to -6]; p = 0.03; extension symmetry index: 114 ± 70 versus 95 ± 63, mean symmetry index difference -19 [95% CI -42 to 4]; p = 0.03; abduction symmetry index: -54 ± 55 versus -41 ± 45, mean symmetry index difference 13 [95% CI -15 to 40]; p = 0.03). A larger length ratio of the residual limb relative to the intact limb was moderately associated with hip moment impulse symmetry in all three anatomical planes of motions both before and 12 months after transfemoral bone-anchored limb implantation, with strong associations observed between postimplantation hip extension and external rotation moment impulse symmetry (extension: ρ = -0.50 [95% CI -0.72 to -0.07]; p = 0.03; internal rotation: ρ = 0.64 [95% CI 0.25 to 0.85]; p = 0.004).
Conclusion: The associations between residual femur length and hip loading symmetry in patients with transfemoral bone-anchored limbs suggest that those with shorter residual limbs will demonstrate more asymmetric joint loading when using a bone-anchored limb. Thus, these findings could potentially be used to better inform targeted interventions based on residual limb morphology, including continued gait training in rehabilitation to promote joint loading symmetry and surgical considerations surrounding limb length changes in those with shorter limbs. Future studies might also examine joint loading symmetry during other activities of daily living after bone-anchored limb implantation to further expand knowledge of how residual limb anthropometry is associated musculoskeletal health after bone-anchored limb implantation.
Level Of Evidence: Level III, therapeutic study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/CORR.0000000000003344 | DOI Listing |
Clin Orthop Relat Res
December 2024
Department of Orthopedics, University of Colorado School of Medicine, Aurora, CO, USA.
J Neuroeng Rehabil
November 2024
Department of Bioengineering, Imperial College London, London, UK.
Background: Direct skeletal fixation, a surgical technique enabling the attachment of an external prosthesis directly to the bone through a percutaneous implant, offers an enticing solution for patients with lower limb amputations facing socket-related issues. However, understanding of its impact on musculoskeletal function remains limited.
Methods: This study compares pre- and 1-year post-osseointegration surgery outcomes, focusing on patient-reported measures and musculoskeletal system function during level-ground walking.
J Hand Surg Am
November 2024
Department of Orthopedic Surgery, Division of Hand & Upper Extremity Surgery, New York University Langone Health, New York City, NY; Center for Amputation Reconstruction, New York University Langone Health, New York City, NY.
Purpose: The purpose of this study was to conduct a systematic review evaluating the reported complications and outcomes of bone-anchored prostheses in digit and partial hand amputees.
Methods: A literature review of primary research articles on osseointegration and bone-anchored prostheses for digit and partial amputees was performed. The Medline, Embase, Scopus, and Cochrane Library databases were queried.
Sci Rep
November 2024
Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia.
Bone-anchored percutaneous implants, commonly referred to as osseointegrated implants, are gaining popularity as an alternative to sockets for attaching a prosthetic limb to an amputated femur. While these implants have several advantages, femoral fractures are relatively common in these patients, occurring in 6.3% of femurs within 4 years.
View Article and Find Full Text PDFProsthet Orthot Int
November 2024
Trauma Research Unit, Department of Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
Background: Bone-anchored protheses (BAPs) by means of osseointegrated implants are increasingly being used in amputees with socket-related issues. Clinical advancements are being published by more and more centers worldwide. Although the number of publications and interest in BAP is growing, a systematic evaluation of scholarly output is lacking.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!