A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A highly sensitive and selective SERS sensors based on Au@PATP@Ag@ZIF-8 for the detection of phosphate in water. | LitMetric

A highly sensitive and selective SERS sensors based on Au@PATP@Ag@ZIF-8 for the detection of phosphate in water.

Talanta

MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou, 510631, China. Electronic address:

Published: December 2024

Rapid and sensitive detection of phosphate is of great significance for ensuring water safety and preventing eutrophication. In this study, we prepared Au@PATP@Ag NRs core-shell structures using 4-aminothiophenol (PATP) as an internal standard signal molecule to enhance the stability of the SERS signal. Based on the protective effect of ZIF-8 on the internal Au@PATP@Ag NRs and the phosphate-induced decomposition of ZIF-8, a phosphate SERS sensor (Au@PATP@Ag@ZIF-8) with high sensitivity, selectivity and stability was designed. This method exhibited a good linear range of 0.1-125 μM and a detection limit of 30 nM. Furthermore, the developed sensor (Au@PATP@Ag@ZIF-8) was effectively applied to assess PO in tap water samples, achieving recoveries between 97.44 % and 104.54 %. With its simple, fast and sensitive features, this method of phosphate detection in water provides a direction for the research and practical application of phosphate detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.127475DOI Listing

Publication Analysis

Top Keywords

detection phosphate
8
au@patp@ag nrs
8
sensor au@patp@ag@zif-8
8
phosphate detection
8
detection
5
phosphate
5
highly sensitive
4
sensitive selective
4
selective sers
4
sers sensors
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!