A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aptamer-based DNAzyme walker electrochemical biosensing strategy for Acinetobacter baumannii detection. | LitMetric

Aptamer-based DNAzyme walker electrochemical biosensing strategy for Acinetobacter baumannii detection.

Bioelectrochemistry

Department of Laboratory Medicine, The Affiliated Hospital of Southwest Medical University, 25 Taiping Street, Luzhou 646000, Sichuan, China; Sichuan Province Engineering Technology Research Center of Molecular Diagnosis of Clinical Diseases, China; Molecular Diagnosis of Clinical Diseases Key Laboratory of Luzhou, Sichuan, China. Electronic address:

Published: December 2024

In this study, an innovative electrochemical biosensor was developed for the rapid, specific, and sensitive detection of Acinetobacter baumannii without the need for sample pretreatment. The biosensor utilized an aptamer as a specific capture probe for A. baumannii and employed a self-powered DNAzyme walker cleavage cycle reaction to achieve signal amplification. Upon introduction of the target bacteria, the aptamer captured the bacteria and released the Trigger, activating the DNAzyme to cleave the substrate chain containing methylene blue (MB). This led to the release of MB-labeled DNA fragments from the electrode surface, resulting in a significant decrease in the square wave voltammetry (SWV) signal of MB on the sensing platform. The limit of detection (LOD) for A. baumannii was determined to be 30 CFU/mL, enabling discrimination of the target bacteria from other common clinical isolates. Furthermore, the biosensor's potential for real sample analysis was demonstrated in cerebrospinal fluid (CSF), showcasing its efficacy and versatility as a biosensing tool with wide-ranging applications in disease diagnosis and bioanalysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bioelechem.2024.108895DOI Listing

Publication Analysis

Top Keywords

dnazyme walker
8
acinetobacter baumannii
8
target bacteria
8
aptamer-based dnazyme
4
walker electrochemical
4
electrochemical biosensing
4
biosensing strategy
4
strategy acinetobacter
4
baumannii
4
baumannii detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!