Fascioliasis, a food-borne trematodiasis, is a disease primarily identified in livestock, such as sheep and cattle. Human fascioliasis has been reported sporadically in Korea, but a recent increase in patients has been associated with a green vegetable juice delivery service. We aimed to investigate the serological and radiological findings of the patients treated for fascioliasis. Patients with peripheral eosinophilia, which is a positive antibody for Fasciola hepatica (F. hepatica) and liver abscess, were considered to have fascioliasis and were treated with triclabendazole at a dose of 10 mg/kg, administered twice. A total of 21 patients diagnosed with fascioliasis were included. Patients were categorized into the early and late diagnosis groups according to the time gap between the presentation and diagnosis. A comparison of initial magnetic resonance imaging (MRI) between the two groups revealed a filling defect of the bile duct that was more commonly observed in the late diagnosis group (72.7% versus 0%; P = 0.003). Hepatic abscess lesions resolved slowly, with 14.3%, 50%, and 85.7% of patients showing complete resolution on computed tomography 6, 12, and 24 months after treatment, respectively. The mean levels of anti-F. hepatica antibodies decreased after a 6-month follow-up (mean levels, onset versus 6-month, 12-month, or 24-month follow-up; 4.36 versus 3.29, 3.17, or 2.31, respectively; all P <0.01). Eosinophil counts reduced significantly 1 month after treatment and remained normal thereafter in both groups. This study suggests that MRI could be useful for diagnosing fascioliasis in a subgroup of patients and that hepatic abscesses and positive antibody results could last for several months after treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4269/ajtmh.24-0162 | DOI Listing |
Sci Rep
January 2025
Department of Electronics, Information and Communication Engineering, Kangwon National University, Samcheok, Republic of Korea.
Detecting brain tumours (BT) early improves treatment possibilities and increases patient survival rates. Magnetic resonance imaging (MRI) scanning offers more comprehensive information, such as better contrast and clarity, than any alternative scanning process. Manually separating BTs from several MRI images gathered in medical practice for cancer analysis is challenging and time-consuming.
View Article and Find Full Text PDFUrol Oncol
January 2025
Research Department, Urovallarta Medical Center, Puerto Vallarta, Mexico.
Background: Multiparametric MRI (Mp-MRI) is a key tool to screen for Prostate Cancer (Pca) and Clinically Significant Prostate Cancer (CsPca). It primarily includes T2-Weighted imaging (T2w), diffusion-weighted imaging (DWI), and Dynamic Contrast-Enhanced imaging (DCE). Despite its improvements in CsPca screening, concerns about the cost-effectiveness of DCE persist due to its associated side effects, increased cost, longer acquisition time, and limitations in patients with poor kidney function.
View Article and Find Full Text PDFJ Neurointerv Surg
January 2025
Institute of Neurointervention, Paracelsus Medical University, Salzburg, Austria.
Background And Purpose: This study evaluates the early clinical performance of the new Artisse Intrasaccular Device (Artisse ISD), a self-expandable intrasaccular flow diverter, for treating wide-necked aneurysms (WNAs). We report initial safety and efficacy outcomes in the first cohort of patients treated with this novel device.
Methods: Prospective clinical and radiological data were collected for all patients treated with the Artisse ISD at three Austrian neurovascular centers from July 2023 to August 2024.
BMJ Open
January 2025
Department of Rehabilitation, Daping Hospital, Army Medical University, Chongqing, China
Introduction: Spasticity is a common complication of stroke, which is related to poor motor recovery and limitations in the performance of activities. Both transcranial magnetic stimulation (TMS) and extracorporeal shockwave therapy (ESWT) are effective treatment methods for poststroke spasticity (PSS). However, there is no existing study exploring the safety and effectiveness of TMS combined with ESWT for PSS.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, College of Chemistry and Chemical Engineering, Ocean University of China, Qingdao 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao 266100, China; Key Laboratory of Ocean Observation and Information of Hainan Province, Sanya Oceanographic Institution, Ocean University of China, Sanya 572024, China. Electronic address:
Improving the adsorption capacity of materials for pollutants by means of modification is an important direction in the research of water treatment technology. To improve the applicability of sodium alginate composites in the field of adsorption, magnetic sodium alginate-based hydrogel microsphere adsorbent material FeO@SA/PEI-Fe (FSPF) was synthesized in a single step by using polyethyleneimine grafting modification of sodium alginate by sol-gel method. The material was used for the removal of direct blue GL (DB 200) and direct date red B (DR 13) from simulated wastewater, as well as Cu(II) and Pb(II) from simulated wastewater with heavy metal ions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!