Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Imaged capillary isoelectric focusing was successfully applied for separating an in-house synthesized closely related peptide pair, that is, a linear 12-mer (Rp5-L) and its cyclic 15-mer variant (Rp5-C). Rp5-L represents a mimotope, that is, an epitope mimicking peptide, of the CD20 antigen, which is over-expressed in B-cell-related tumors. Peptide identity-including the successful disulfide bond formation in Rp5-C-was confirmed with matrix-assisted laser desorption ionization-time of flight mass spectrometry. The purity of synthesized products was determined by a reversed-phase high-performance liquid chromatographic method with ultraviolet detection. The apparent isoelectric point (pI) of cyclic Rp5-C and Rp5-L was 5.99 and 6.47, respectively. An appropriate combination of carrier ampholytes allowed for their baseline separation with an analysis time of <20 min. Method validation was done for the synthesized peptides and three flanking pI markers covering, for example, repeatability and intermediate precision. Calibrations on different days resulted in identical slopes for Rp5-L and Rp5-C, respectively, as statistically confirmed by Welch's t-test and pooled t-test over 8 days. The calibration data of mimotopes and pI markers were evaluated for outliers, normality, homoscedasticity, and autocorrelation with complementary statistical procedures, which identified an otherwise unnoticed outlier for a pI marker. The linearity of calibration for Rp5-L, Rp5-C, and the pI markers was tested with Mandel's fitting test and lack-of-fit test. For Rp5-L and Rp5-C, the calculated limits of detection and limits of quantification were ≤0.31 and ≤0.96 µmol/L, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jssc.70054 | DOI Listing |
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11685353 | PMC |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!