A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multicriteria assessment of optical coherence tomography using non-raster trajectories. | LitMetric

Multicriteria assessment of optical coherence tomography using non-raster trajectories.

J Microsc

Université de Franche-Comté, CNRS, AS2M Department, FEMTO-ST Institute, Besançon, France.

Published: December 2024

This article presents a qualitative, quantitative, and experimental analysis of optical coherence tomography (OCT) volumes obtained using different families of non-raster trajectories. We propose a multicriteria analysis to be used in the assessment of scan trajectories used in obtaining OCT volumetric point cloud data. The novel criteria includes exploitation/exploration ratio of the OCT data obtained, smoothness of the scan trajectory and fast preview of the acquired OCT data in addition to conventional criteria; time and quality (expressed as volume similarity rather than slice-by-slice image quality). The set of criteria proposed will be useful in assessing OCT scan trajectories for optimisation in various applications including robot assisted in vivo optical biopsy. We show in this paper that the rate of data acquisition is improved without degrading the OCT volume quality by scanning using non-raster trajectories (they are fast, smooth, and make the galvanometer scanners have less wear and tear). In particular, the rosette scan trajectory, which was the preferred non-raster trajectory, provided a balanced performance in having better clarity at the centre and periphery of the scanned object.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jmi.13383DOI Listing

Publication Analysis

Top Keywords

non-raster trajectories
12
optical coherence
8
coherence tomography
8
scan trajectories
8
oct data
8
scan trajectory
8
oct
6
trajectories
5
multicriteria assessment
4
assessment optical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!