Hand-held ultrasound devices (HHUD) are increasingly used in routine clinical practice, though they lacked continuous (CW) Doppler capability until recent times. There is limited evidence on the utility of HHUD in assessing aortic stenosis (AS) in real-world settings. Our goal was to validate a new HHUD with CW Doppler assessing AS hemodynamic severity. An observational, single-center study at the Valdecilla University Hospital, Santander, Spain between October 2022 and August 2023 was conducted. Patients previously diagnosed with AS were consecutively recruited. Following a reference echocardiographic examination in the cardiac imaging laboratory by an experienced operator (American Society of Echocardiography, level III), a HHUD with CW Doppler (Kosmos, EchoNous™) was used by an operator with intermediate echocardiography experience (American Society of Echocardiography, level II). The focus was on measuring aortic transvalvular Doppler velocities. Agreement between the mean trans-aortic gradient (mAG) was assessed using the intraclass correlation coefficient (ICC) test. A total of 101 patients were included. The reference test obtained a mAG of 29 mmHg [19.8-42.2], while the HHUD test showed 27.2 mmHg [16.2-43.9]. A strong correlation was observed (r = 0.89), with an ICC value of 0.87 and no significant bias (1.61 ± 0.9). The HHUD demonstrated very good ability to identify severe AS (kappa = 0.81, 95% CI 0.68-0.94; global agreement 92.1%) and good agreement for moderate (kappa = 0.58; global agreement = 80.2%) and mild (kappa = 0.73; global agreement = 88.1%) AS. Agreement was lower in patients with obesity (ICC = 0.63), poor acoustic windows (ICC = 0.74), or atrial fibrillation (ICC = 0.74). The HHUD showed good agreement with standard echocardiography in assessing AS. While it slightly underestimated mAG, it was accurate enough to reliably quantify AS severity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-024-03320-7DOI Listing

Publication Analysis

Top Keywords

hand-held ultrasound
8
aortic stenosis
8
hhud doppler
8
american society
8
society echocardiography
8
echocardiography level
8
good agreement
8
hhud
7
agreement
5
validation hand-held
4

Similar Publications

Hand-held ultrasound devices (HHUD) are increasingly used in routine clinical practice, though they lacked continuous (CW) Doppler capability until recent times. There is limited evidence on the utility of HHUD in assessing aortic stenosis (AS) in real-world settings. Our goal was to validate a new HHUD with CW Doppler assessing AS hemodynamic severity.

View Article and Find Full Text PDF

Subcoracoid impingement occurs due to mechanical encroachment of the subscapularis tendon in the subcoracoid space between the coracoid process and lesser tuberosity of the humerus. Although physical therapy is known to have a crucial role in managing this condition, to the best of our knowledge, there is no established physical therapy program in the literature. This case report aims to provide a detailed presentation and diagnosis of a subcoracoid impingement case and to investigate the effects of physical therapy on pain, disability, performance, muscle strength, and ultrasound measurements over a one-year follow-up period.

View Article and Find Full Text PDF

Mechanical ventilation with high tidal volume (TV) or positive end-expiratory pressure (PEEP) may induce lung overinflation and increased pulmonary vascular resistance to flow. In 8 healthy mechanically ventilated pigs, we evaluated whether incident dark field (IDF) vital microscopy, applied through a small thoracotomy, could be used to evaluate changes in alveolar and pulmonary microvessel dimensions under different ventilator settings. High TV (12 ml/kg) increased alveolar diameters (from 99 ± 13 to 114 ± 6 μm, p < 0.

View Article and Find Full Text PDF

Primary manipulation knowledge of objects is associated with the functional coupling of pMTG and aIPS.

Neuropsychologia

December 2024

Proaction Laboratory, Faculty of Psychology and Educational Sciences, University of Coimbra, Portugal; CINEICC, Faculty of Psychology and Educational Sciences, University of Coimbra, Portugal. Electronic address:

Correctly using hand-held tools and manipulable objects typically relies not only on sensory and motor-related processes, but also centrally on conceptual knowledge about how objects are typically used (e.g. grasping the handle of a kitchen knife rather than the blade avoids injury).

View Article and Find Full Text PDF

Background And Purpose: Sonothrombolysis is a potential adjunctive therapy for large vessel occlusion (LVO) stroke. Bedside ultrasound image-guided high-intensity focused ultrasound (HIFU) therapy could deliver higher energy therapeutic ultrasound to the thrombus with higher precision than what was previously accomplished in human trials. The aim is to test the feasibility of diagnostic transcranial contrast-enhanced ultrasound (CEUS) to image the occlusion site and continuously maintain the guidance image on-target for a sufficient exposure time for HIFU to be effective during LVO stroke evaluation and treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!