An electrochemiluminescence (ECL) immunosensor was developed for the highly sensitive and specific detection of heart-type fatty acid binding protein (H-FABP) and the rapid diagnosis of acute myocardial infarction (AMI). H-FABP is a biomarker that is highly specific to cardiac tissue and is associated with a range of cardiac diseases. Following myocardial injury, the rate of increase in H-FABP levels is greater than that observed for myoglobin and troponin. Therefore, the measurement of H-FABP is crucial for the early exclusion of AMI. Silver-cysteine nanorod (AgCysNR), which served as the ECL emitter, was produced with a one-step, green, simple, template-free aqueous phase method. The surfaces of AgCysNR displayed many amino and carboxyl groups that were connected to a large number of a secondary H-FABP-specific antibody. Ferrum-doped molybdenum oxide (FeMoO), with a large specific surface area, was richly decorated with silver nanoparticle (AgNP), which increased the interfacial electron transfer rate of FeMoO. The AgNP was used as a co-reaction accelerator to promote persulfate to produce more sulfate anion radical and then enhance the ECL intensity of AgCysNR. The linear range of the ECL immunosensor was 10 fg/mL to 100 ng/mL, and the detection limit was 2.3 fg/mL (signal/noise = 3). The sensor was determined to be stable, repeatable, and reproducible, and the method achieved recoveries of 101.0 to 102.6% with relative standard deviations of 1.4 to 2.0%. This immunosensor represents a promising tool for the early diagnosis of AMI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00604-024-06923-y | DOI Listing |
Mikrochim Acta
December 2024
State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Collaborative Innovation Center for Guangxi Ethnic Medicine, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China.
An electrochemiluminescence (ECL) immunosensor was developed for the highly sensitive and specific detection of heart-type fatty acid binding protein (H-FABP) and the rapid diagnosis of acute myocardial infarction (AMI). H-FABP is a biomarker that is highly specific to cardiac tissue and is associated with a range of cardiac diseases. Following myocardial injury, the rate of increase in H-FABP levels is greater than that observed for myoglobin and troponin.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!