Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Ketamine is a dissociative anesthetic drug that is abused by teenagers and young adults, commonly for recreational purposes in dance clubs, to generate euphoria and dissociation, and sometimes employed as a date-rape drug. Herein, a highly sensitive, and environmentally friendly spectrofluorimetric method was developed for detection of ketamine in pharmaceutical and plasma samples. The technique is based on a nucleophilic substitution reaction occurring between ketamine and NBD-Cl (4-chloro-7-nitrobenzo-2-oxa-1,3-diazole), resulting in the formation of a fluorescent derivative that exhibits detectability at a remarkable level. The resultant derivative demonstrates its maximum emission intensity at 543 nm upon excitation at a wavelength of 481 nm. Upon optimizing the reaction parameters, a linear relationship was established between the fluorescence intensity of the formed derivative and the concentrations of ketamine within the specified range of 10 - 250 ng/mL. The method demonstrated exceptional sensitivity with detection and quantitation limits of 2.37 ng/mL and 7.18 ng/mL, respectively, allowing for the detection of ketamine in both pharmaceutical and plasma samples. The method was precise (%RSD < 1) accurate (%R = 99.74%) and robust (% R ± SD from 98.00 ± 1.11 to 99.97 ± 0.75). Furthermore, the developed method was compared to the reported method, with the results indicating that the suggested method is more sensitive and ecologically benign.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11686382 | PMC |
http://dx.doi.org/10.1038/s41598-024-82427-2 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!