A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inducing cylindrical and spherical defocus after implantation with new generation intraocular lenses improves intermediate and near visual acuity. | LitMetric

An induced cylinder and spherical power after implantation with an extended depth of focus (EDOF) and enhanced monofocal intraocular lens (IOL) could improve distance, intermediate (60 cm) and near (40 cm) visual acuity (VA). In this prospective study, forty eyes with Eyhance EDOF IOL (Johnson and Johnson, USA) and 40 eyes with Vivity EDOF IOL (Alcon Laboratories Inc. USA) were included. Induced cylinder (applied to non-dominant eye) in steps of + 0.25D were used and then VA was measured monocularly (only non-dominant eye). Similarly, induced sphere (applied to non-dominant eye) in steps of + 0.25D were used and then VA was measured monocularly (only non-dominant eye). The above methods were repeated for the dominant eye as well. Then, binocular defocus curve for each patient was obtained by inducing optimal sphere and cylinder (one at a time in front of the non-dominant eye only). In both IOL groups, induced cylinder and sphere independently led to significant improvement in near and distance vision (p < 0.05). Induced sphere binocularly caused a greater decrease (~ 0.1 LogMAR) in distance VA compared to induced cylinder but this was not clinically significant. Most patients accepted an induced cylinder of +1.0 to +1.5D in both IOL groups. Induced cylinder and sphere caused a favourable improvement in near and intermediate VA after surgery in both IOL groups without a significant drop in distance VA.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41598-024-83387-3DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11686359PMC

Publication Analysis

Top Keywords

non-dominant eye
20
induced cylinder
12
visual acuity
8
edof iol
8
applied non-dominant
8
eye steps
8
steps + 025d
8
+ 025d measured
8
measured monocularly
8
monocularly non-dominant
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!