Traditional beat frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) are limited by short energy accumulation times and the necessity of a decay period, leading to weaker signals and longer measurement cycles. Herein, we present a novel optomechanical energy-enhanced (OEE-) BF-QEPAS technique for fast and sensitive gas sensing. Our approach employs periodic pulse-width modulation (PWM) of the laser signal with an optimized duty cycle, maintaining the quartz tuning fork's (QTF) output at a stable steady-state level by applying stimulus signals at each half-period and allowing free vibration in alternate half-periods to minimize energy dissipation. This method enhances optomechanical energy accumulation in the QTF, resulting in an approximate 33-fold increase in response speed and a threefold increase in signal intensity compared to conventional BF-QEPAS. We introduce an energy efficiency coefficient to quantify the relationship between transient signal amplitude and measurement duration, exploring its dependence on the modulation signal's period and duty cycle. Theoretical analyses and numerical simulations demonstrate that the maximum occurs at a duty cycle of 50 % and an optimized beat frequency Δ of 30 Hz. Experimental results using methane reveal a detection limit of 2.17 ppm with a rapid response time of 33 ms. The OEE-BF-QEPAS technique exhibits a wide dynamic range with exceptional linearity over five orders of magnitude and a record noise-equivalent normalized absorption (NNEA) coefficient of 9.46 × 10 W cm Hz. Additionally, a self-calibration method is proposed for correcting resonant frequency shifts. The proposed method holds immense potential for applications requiring fast and precise gas detection.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11683322 | PMC |
http://dx.doi.org/10.1016/j.pacs.2024.100677 | DOI Listing |
Sci Rep
January 2025
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
This paper describes the design and initial proof-of-concept of a single pre-clinical transcranial focused ultrasound (FUS) system capable of performing histotripsy (mechanical ablation), hyperthermia, blood-brain barrier opening (BBBO), sonodynamic therapy, or neuromodulation in a murine brain. We have termed it the All-in-One FUS system for murine brain studies, which is the first FUS system of its kind. The 1.
View Article and Find Full Text PDFSci Rep
January 2025
SINTEF, Department of Health Research and Department of Circulation and Medical Imaging, The Norwegian University of Science and Technology NTNU, 7491, Trondheim, Norway.
The transport of drugs into tumor cells near the center of the tumor is known to be severely hindered due to the high interstitial pressure and poor vascularization. The aim of this work is to investigate the possibility to induce acoustic streaming in a tumor. Two tumor cases (breast and abdomen) are simulated to find the acoustic streaming and temperature rise, while varying the focused ultrasound transducer radius, frequency, and power for a constant duty cycle (1%).
View Article and Find Full Text PDFTheranostics
January 2025
College of Pharmacy, Seoul National University, Seoul 08826, South Korea.
Hypoxia is a major obstacle in the treatment of solid tumors because it causes immune escape and therapeutic resistance. Drug penetration into the hypoxic regions of tumor microenvironment (TME) is extremely limited. This study proposes using the unidirectional fluid flow property of low-intensity pulsed ultrasound (LIPUS) to overcome drug penetration limitations in the TME.
View Article and Find Full Text PDFNature
January 2025
Perimeter Institute for Theoretical Physics, Waterloo, Ontario, Canada.
Fast radio bursts (FRBs) last for milliseconds and arrive at Earth from cosmological distances. Although their origins and emission mechanisms are unknown, their signals bear similarities with the much less luminous radio emission generated by pulsars within our Miky Way Galaxy, with properties suggesting neutron star origins. However, unlike pulsars, FRBs typically show minimal variability in their linear polarization position angle (PA) curves.
View Article and Find Full Text PDF3D Print Addit Manuf
October 2024
Department of Aircraft Manufacturing Engineering, School of Aerospace Engineering, Guizhou Institute of Technology, Guiyang, China.
The application of a pulsed magnetic field (PMF) during a metallurgy solidification process has proven to be an effective method in refining the grain size and improving the mechanical performance of the material. However, fewer works were reported in the realm of laser additive manufacturing (LAM) and the mechanism of grain refinement consequent to the PMF is still unclear. In this work, numerical models were developed to study the thermal-fluid characteristics in the Ti-alloy melt pool generated during the laser scanning process under the effect of a combined direct current (DC) electric field and PMF.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!