A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigating the effects of co-exposure to noise and benzene on serum oxidative stress in rat. | LitMetric

Occupational exposures are generally complex, workers are exposed with more than one hazardous agent in work environment. Combined exposure to noise and benzene is common in occupational environments. Sub-acute exposure to benzene vapors can induce oxidative stress in serum. Additionally, noise exposure leads to non-auditory effects, such as oxidative stress. However, In the authors' research scope, a study aimed at investigating the effect of co-exposure to noise and benzene on the oxidative stress of rat serum has not been found. The purpose of this study is to investigate the effect of co-exposure to noise and benzene on oxidative stress. In this study, 24 Wistar albino male rats were divided into four groups: the control group (1), the group exposed to white noise with an intensity of 100 dB and a frequency of 250-8KHz (2), the group exposed to benzene vapors with a concentration of 300 PPM (3), and the group co-exposed to white noise with an intensity of 100 dB and benzene vapors with a concentration of 300 PPM. Oxidative stress induced was investigated by serum oxidative stress indices, including lipid peroxidation (MDA), total oxidative capacity (TOS), and antioxidant activity indices (SOD) and (GSH), as well as total antioxidant capacity (TAC).The results showed that exposure to noise and benzene, both separately and combined, can lead to oxidative stress in rat serum, increasing serum oxidant indices MDA and TOS while decreasing serum antioxidant indices TAC, SOD, and GSH was detected in groups exposed to noise and benzene. The findings indicate that the serum oxidative stress caused by the co- exposure to noise and benzene is significantly higher than separate exposure to noise or benzene, also Co-exposure to noise and benzene can have an almost additive effect on increasing serum oxidative stress in rats. This study highlights the importance of studying co-exposure to physical and chemical hazardous agents in the work environment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11681911PMC
http://dx.doi.org/10.1016/j.toxrep.2024.101849DOI Listing

Publication Analysis

Top Keywords

oxidative stress
40
noise benzene
36
co-exposure noise
16
serum oxidative
16
exposure noise
16
noise
12
benzene
12
stress rat
12
benzene vapors
12
oxidative
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!