Background: Visceral leishmaniosis (VL) is the most severe form of human leishmaniosis, with an estimated 95% case fatality if left untreated. Dogs act as peridomestic reservoir hosts for the protozoan parasite Leishmania infantum, a causative agent for human leishmaniosis, endemic throughout the Mediterranean basin. To assure consistent and accurate surveillance of canine infection and prevent transmission to people, consistent diagnosis of canine L. infantum infection across this region is essential for protecting both human and animal health. Our goal was to compare the accuracy, sensitivity and specificity of enzyme-linked immunosorbent assays (ELISA) and immunofluorescence antibody tests (IFAT), performed at seven academic veterinary diagnostic centres across southern Europe and Israel.
Methods: We performed a known sample "ring" trial to compare L. infantum quantitative serological tests. Two hundred seventy-two (n = 272) canine serum samples of known serological status were chosen from these sites, representative of the region. In-house or commercial ELISA and IFAT were performed according to each laboratory's specifications. Latent Class Analysis (LCA) was used to determine sensitivity and specificity of each test. True and false positives were calculated to determine the probability of identifying samples.
Results: Sensitivity and specificity for ELISA ranged from 95 to 99% and 92% to 97%, respectively, with moderate variability from one site. Sensitivity and specificity for IFAT ranged from 89 to 99% and 83% to 94%, respectively, with increased variability compared to ELISA. Overall test agreement was 78% with a pair-wise agreement between 65 and 89%.
Conclusions: All sites demonstrated substantial comparative diagnostic accuracy, with good agreement based on known seropositive and seronegative samples. Studies and interventional trials that use these tests will remain valid because of high diagnostic agreement between sites.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1186/s13071-024-06631-9 | DOI Listing |
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11684067 | PMC |
Eur J Breast Health
January 2025
Department of Surgery, Salmaniya Medical Complex, Government Hospitals, Manama, Bahrain.
Objective: Neoadjuvant chemotherapy (NACT) has been the primary treatment method for patients with local advanced breast cancer. A pathological complete response (pCR) to therapy correlates with better overall disease prognosis. Magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) have been widely used to monitor the response to NACT in breast cancer.
View Article and Find Full Text PDFEur J Breast Health
January 2025
Department of Biomedical Engineering, Yeditepe University Faculty of Engineering, İstanbul, Turkey.
Objective: To investigate integrating an artificial intelligence (AI) system into diagnostic breast ultrasound (US) for improved performance.
Materials And Methods: Seventy suspicious breast mass lesions (53 malignant and 17 benign) from seventy women who underwent diagnostic breast US complemented with shear wave elastography, US-guided core needle biopsy and verified histopathology were enrolled. Two radiologists, one with 15 years of experience and the other with one year of experience, evaluated the images for breast imaging-reporting and data system (BI-RADS) scoring.
Anal Methods
January 2025
Department of Colorectal Surgery, College of Clinical Medicine for Oncology, Fujian Medical University, Fuzhou, Fujian, China.
MicroRNA (miRNA) is a promising biomarker for the early diagnosis of pancreatic cancer. To enable sensitive and reliable miRNA detection, we have developed a one-pot isothermal CRISPR/Dx detection system by combining rolling circle amplification (RCA) and CRISPR/Cas12a. RCA and CRISPR/Cas12a reactions are carried out in a single closed tube, bypassing the transferring step.
View Article and Find Full Text PDFWorld J Orthop
December 2024
Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA 02114, United States.
Background: Pes planus (flatfoot) and pes cavus (high arch foot) are common foot deformities, often requiring clinical and radiographic assessment for diagnosis and potential subsequent management. Traditional diagnostic methods, while effective, pose limitations such as cost, radiation exposure, and accessibility, particularly in underserved areas.
Aim: To develop deep learning algorithms that detect and classify such deformities using smartphone cameras.
Infect Dis Clin Microbiol
December 2024
Department of Medical Microbiology, Bursa Uludağ University School of Medicine, Bursa, Türkiye.
Objective: The study compared the mö-screen Corona Antigen Test (Qiagen, Germany) with RT-PCR in suspected COVID-19 patients.
Materials And Methods: Two hundred combined oro-nasopharyngeal swabs were collected from patients with suspected COVID-19 to evaluate the analytical performance of the mö-screen Corona Antigen Test compared to qualitative real-time reverse transcriptase polymerase chain reaction (RT-PCR) in symptomatic patients.
Results: The mö-screen Corona Antigen Test showed an overall agreement with a sensitivity of 100%, a specificity of 100%, a positive predictive value (PPV) of 100%, and a negative predictive value (NPV) of 100%.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!