Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Knowing the available dental space in a patient is crucial for orthodontists to develop a good treatment plan.
Objectives: To compare and evaluate the reliability, reproducibility, and accuracy of three measurement methods on models: conventional, mobile app, and digital software.
Materials And Methods: Maxillary and mandibular dental plaster models of 20 subjects with permanent dentition were analyzed. Three measurements were taken: manually using a digital caliper, using Nemocast 3D software, and using the mobile app "Ruler." These were performed by the same observer at the same initial time (T1) and repeated after 15 days (T2).
Results: The three methods measured each of the quadrants and each of the dental pieces similarly, with no significant differences found. Significant differences were found between the different measurement times in the manual and app ruler measurement groups. Intra-observer consistency was also observed through Pearson correlations. The measurement from the mobile app "Ruler" presented lower values compared to the other two models, especially with the measurements taken for each quadrant.
Conclusion: The three methods used for measuring dentoskeletal discrepancy are similar in terms of results. However, Nemocast 3D software showed greater reproducibility and reliability compared to the other two methods presenting consistency in the results measured at both time points, which may be useful for our diagnoses.
Trial Registration: The study was conducted according to the ethical standards set by the Declaration of Helsinki for Biomedical Research and the protocol was approved by the Bioethics Committee of the University of Salamanca with number 23/1074.